Manitowoc Ice Q130 manual Installation Instructions, Location of Ice Machine, Section

Models: Q130

1 40
Download 40 pages 32.69 Kb
Page 10
Image 10
Installation Instructions

Installation Instructions

Section 2

 

 

Location of Ice Machine

The location selected for the ice machine must meet the following criteria. If any of these criteria are not met, select another location.

The location must be indoors.

The location must be free of airborne and other contaminants.

The air temperature must be at least 40°F (4.4°C), but must not exceed 110°F (43.4°C).

The location must not be near heat-generating equipment or in direct sunlight.

The location must be capable of supporting the weight of the ice machine and a full bin of ice.

The location must allow enough clearance for water, drain and electrical connections in the rear of the ice machine.

The location must not obstruct airflow through or around the ice machine (condenser airflow is in and out the front). Refer to the chart below for clearance requirements.

 

Self-Contained

Self-Contained

 

Air-Cooled

Water-Cooled

 

 

 

Top/Sides

5” (203 mm)*

5” (127 mm)*

 

 

 

Back

5” (127 mm)*

5” (127 mm)*

 

 

 

NOTE: The ice machine may be built into a cabinet.

There is no minimum clearance requirement for the top or left and right sides of the ice machine. The listed values are recommended for efficient operation and servicing only.

!Caution

The ice machine must be protected if it will be subjected to temperatures below 32°F (0°C). Failure caused by exposure to freezing temperatures is not covered by the warranty. See “Removal from Service/Winterization” Section 4.

Ice Machine Heat of Rejection

Series

Heat of Rejection*

Ice Machine

Air Conditioning**

Peak

 

 

 

Q130

2400

2900

 

 

 

Q210

2400

3400

 

 

 

Q270

3800

6000

 

 

 

*B.T.U./Hour

**Because the heat of rejection varies during the ice making cycle, the figure shown is an average.

Ice machines, like other refrigeration equipment, reject heat through the condenser. It is helpful to know the amount of heat rejected by the ice machine when sizing air conditioning equipment where self-contained air- cooled ice machines are installed.

2-2