FAULT | PROBLEM | COMPONENTS | TO CHECK | |
CODES | ||||
|
|
| ||
F1 | Power to element relay activated J1, J2 wire harness connection to control shorted. If | |||
during time of day display, | checks ok, change control. |
| ||
|
| |||
F2 | Over temperature sensed | Ohm TEST SENSOR. If checks ok, change control. | ||
F3 | Open sensor. | Ohm sensor. |
| |
F4 | Shorted sensor. | Ohm sensor. |
| |
F5 | Over temperature | Ohm sensor. Check connection of sensor wire harness. | ||
F7 | Shorted key | Stuck Function Key on control. |
| |
F9 | Door Code | Check Latch Assembly. |
|
For Models:
W27100, W27200, W30100, WW27210, WM27260 (Oven Sensor Chart: Please refer to chart below)
MEAT PROBE: |
| OVEN SENSOR: |
| |
|
|
| ||
TYPE: | NTC thermistor | SENSOR TYPE: | RTD 1000 ohm platinum | |
CALIBRATION: |
| |||
9938 ohms (150 F) | CALIBRATION: | |||
1654 ohms (350 F) | ||||
| ||||
PROBE RESISTANCE VS TEMR TABLE | OVEN SENSOR RESISTANCE VS TEMR TABLE | |||
|
| |||
DEGREES F | RESISTANCE | DEGREES F | RESISTANCE | |
|
| |||
122 | 18963 ohms | 100 | 1143 ohms | |
150 | 9938 | 200 | 1350 | |
156.2 | 8846 | 300 | 1553 | |
165.2 | 7456 | 350 | 1654 | |
210.1 | 3886 | 400 | 1753 | |
|
| 500 | 1949 | |
|
| 600 | 2142 | |
|
| 700 | 2331 | |
|
| 800 | 2516 | |
|
| 900 | 2697 | |
|
| 1000 | 2874 |
For Models:
W27400, W30400, W30400RWW27430, WW27430RWW30430, WW30430RWM27460,
WM30460, JJW8527, JJW85300 JJW86270 JJW8630, JJW9527, JJW9530, JJW9627, JJW9630, JMW8527, JMW8530, JMW9527, JMW9530
16009721 | COMPONENT DESCRIPTION | |
| ©1999 Maytag Appliances Sales Company |
|