While in the test mode the following outputs may be checked:
Bake Pad-
Broil Pad-
Convect Bake Pad-
Press the pad in the test mode and the bake relay will be activated.
Press the pad in the test mode and the broil relay will be activated.
Press the pad in the test mode and the convect bake relay will be activated.
Convect Roast
Oven Light Pad-
Probe Pad-
Timer-
Stop Time Pad-
Clock Pad-
Press the pad in the test mode and the oven light relay will be activated.
Press the probe pad in the test mode and the probe temperature will
be displayed.
Press the timer pad in the test mode and the factory codes will appear and the oven temp will appear in red.
Press the stop time pad in the test mode and the beeper will be activated and the control ID will be displayed in the blue digits and the power relay board ID will be displayed in the red temperature digits.
Press the clock pad in the test mode and all display segments will be activated.
Clock Time Pad- Press the clock time pad in the test mode and the last fault code sensed in the system will be displayed.
Digital Input Pads- Press the digital input pads in the test mode and the digit that has been pressed will be displayed.
Clean Key-Press the clean key pad in the test mode and the state of the door lock switches and the status of the user selectable options will be displayed.