DOOR LOCK SWITCH CODES
| UNLOCKED |
| DOOR CLOSED |
DISPLAY CODES | SWITCH | LOCKED SWITCH | SWITCH |
7 | CLOSED | CLOSED | CLOSED |
6 | OPEN | CLOSED | CLOSED |
5 | CLOSED | OPEN | CLOSED |
i |
|
|
|
!4 | OPEN | OPEN | OPEN |
3 | CLOSED | CLOSED | OPEN |
2 | OPEN | CLOSED | OPEN |
1 | CLOSED | OPEN | OPEN |
0 | OPEN | OPEN | OPEN |
For JJW Models |
|
|
|
To test the control the following should be performed:
Bake Pad-
Broil Pad-
Touch the bake pad then touch the auto set pad within 4 seconds of each other. The bake relay should engage and the element start to heat. Listen for the relay and then check for heat from the element.
Touch the broil pad and then touch the auto set pad within 4 seconds of each other. The broil relay should engage and the element start to heat. Listen for the relay and then check for heat from the element.
Convect Bake Pad- Touch the convect broil pad and then touch the auto set pad within four seconds of each other. The convect bake relay should engage, the fan should come run on low speed, end the element start to heat. Listen for the relay, the fan, and then check for heat from the element. ,
Convect Roast
Drying Pad-
Clean Pad-
Touch the drying pad and then the auto set pad within four seconds of each other. The fan should start and the element should start to heat. Listen for the fan and check for heat from the element.
Touch the clean pad and then the auto set pad within four seconds of each other. The relay should engage, the door lock motor energize, and the door lock. Listen for the relay, the motor to energize, and check the door to make sure it locks.
16009721 | "[ROUBLESHOO'nNG | |
| @1999 Maytag Appliances Sales Company |
|