Desa VYGF33NRB Cleaning And Maintenance, Burner Primary Air Holes, Main Burner, Continued

Models: VYGF33PRB, VYGF33NRB, FPVF33PRA, FPVF33NRA VYGF33NRB VYGF33PRB

1 40
Download 40 pages 23.19 Kb
Page 21
Image 21
BURNER PRIMARY AIR HOLES

INSPECTING BURNERS

Burner Primary Air Holes

Main Burner

Burner Flame Pattern

CLEANING AND MAINTENANCE

Cleaning Burner Injector Holder and Pilot Air Inlet Hole

21

INSPECTING BURNERS

Continued

BURNER PRIMARY AIR HOLES

Air is drawn into the burner through the holes in the fitting at the burner entrance. These holes may become blocked with dust or lint. Periodically inspect these holes for any blockage and clean if needed. Blocked air holes will create soot.

MAIN BURNER

Periodically inspect all burner flame holes with the fireplace run- ning. All slotted burner flame holes should be open with yellow flame present. All round burner flame holes should be open with a small blue flame present. Some burner flame holes may become blocked by debris or rust, with no flame present. If so, turn off fireplace and let cool. Remove blockage. Blocked burner flame holes will create soot.

BURNER FLAME PATTERN

MAIN BURNER WARNING: If yellow tipping occurs, your fireplace could produce increased levels of carbon monoxide.

NOTICE: Do not mistake orange flames with yellow tipping. Dirt or other fine particles enter the fireplace and burn causing brief patches of orange flame.

Figure 45 shows a correct burner flame pattern. Figure 46 shows an incorrect burner flame pattern. The incorrect burner flame pattern shows the flame higher consistently higher than 1 inch above the logs.

If burner flame pattern is incorrect, as shown in Figure 46

turn heater off (see To Turn Off Gas To Appliance, page 19)

see Troubleshooting, pages 23 through 25

CLEANING AND

MAINTENANCE

BURNER FLAME PATTERN WARNING: Turn off fireplace and let cool before cleaning.

CLEANING AND CAUTION: You must keep control areas, burner, and circulating air passageways of fireplace clean. Inspect these areas of fireplace before each use. Have fireplace inspected yearly by a qualified service person. Fireplace may need more frequent cleaning due to excessive lint from carpeting, bedding mate- rial, pet hair, etc.

CLEANING BURNER INJECTOR HOLDER AND PILOT AIR INLET HOLE

The primary air inlet holes allow the proper amount of air to mix with the gas. This provides a clean burning flame. Keep these holes clear of dust, dirt, lint, and pet hair. Clean these air inlet holes prior to each heating season. Blocked air holes will create soot. We recommend that you clean the unit every three months during operation and have heater inspected yearly by a qualified service person.

We also recommend that you keep the burner tube and pilot assembly clean and free of dust and dirt. To clean these parts we recommend using compressed air no greater than 30 PSI. Your local computer store, hardware store, or home center may carry com- pressed air in a can. You can use a vacuum cleaner in the blow position. If using compressed air in a can, please follow the direc- tions on the can. If you don't follow directions on the can, you could damage the pilot assembly.

1.Shut off the unit, including the pilot. Allow the unit to cool for at least thirty minutes.

2.Inspect burner, pilot, and primary air inlet holes on injector holder for dust and dirt (see Figure 47 and Figure 48, page 22).

3.Blow air through the ports/slots and holes in the burner.

4.Check the injector holder located at the end of the burner tube again. Remove any large particles of dust, dirt, lint, or pet hair with a soft cloth or vacuum cleaner nozzle.

Figure 45 - Correct Burner Flame Pattern

Yellow Tipping

Figure 46 - Incorrect Burner Flame Pattern

Burner

Tube

Primary Air Inlet Holes (Shape of Holes May Vary by Model)

Injector Holder (May Be Brass or Aluminum Depending on Model)

Figure 47 - Injector Holder On Outlet Burner Tube

Manual backgroundFor moreManual backgroundManual backgroundManual backgroundvisit www.Manual backgroundManual backgroundManual background.comManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background

110148-01A

Page 21
Image 21
Desa VYGF33NRB Cleaning And Maintenance, Burner Primary Air Holes, Main Burner, Burner Flame Pattern, Inspecting Burners