Desa VYGF33PRB Maintenance, page, ing Gas Connections, page, Troubleshooting, Continued, Remedy

Models: VYGF33PRB, VYGF33NRB, FPVF33PRA, FPVF33NRA VYGF33NRB VYGF33PRB

1 40
Download 40 pages 23.19 Kb
Page 25
Image 25
Maintenance, page 21)

TROUBLESHOOTING

25

TROUBLESHOOTING

Continued

ing Gas Connections, page 14) WARNING: If you smell gas

Shut off gas supply.

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

IMPORTANT: Operating fireplace where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors. These odors will disappear over time.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Fireplace produces a clicking/ticking noise just after burner is lit or shut off

1.Metal expanding while heating or con- tracting while cooling

1.This is common with most heaters. If noise is excessive, contact qualified ser- vice person

Fireplace produces unwanted odors

1.

Heater burning vapors from paint, hair

 

 

spray, glues, cleaners, chemicals, new

 

 

carpet, etc. (See IMPORTANT state-

 

 

ment above)

 

2.

Low fuel supply (propane/LP only)

 

3.

Gas leak. See Warning statement

 

 

at top of page

1.Open window to ventilate room. Stop us- ing odor causing products while heater is running

2.Refill supply tank (propane/LP only)

3.Locate and correct all leaks (see Check- ing Gas Connections, page 14)

Fireplace shuts off in use (ODS operates)

1.

Not enough fresh air is available

1.

Open window and/or door for ventilation

 

2.

Low line pressure

2.

Contact local natural or propane/LP gas

 

 

 

 

company

 

3.

ODS/pilot is partially clogged

3.

Clean ODS/pilot (see Cleaning and

 

 

 

 

Maintenance, page 21)

 

 

 

 

 

Gas odor even when control knob is in OFF

1.

Gas leak. See Warning statement

1.

Locate and correct all leaks (see Check-

position

 

at top of page

 

ing Gas Connections, page 14)

 

2.

Control valve or gas control defective

2.

Replace control valve or gas control

Gas odor during combustion

1.

Foreign matter between control valve

 

 

and burner

 

2.

Gas leak. See Warning statement

 

 

at top of page

1.Take apart gas tubing and remove for- eign matter

2.Locate and correct all leaks (see Check- ing Gas Connections, page 14)

Dark residue on logs inside of their fireplace

1.

Improper log placement

1.

Properly locate logs (see Installing Logs,

Note: After removing all causes of residue

 

 

 

pages 15 and 16)

deposits, completely clean fireplace and ap-

2.

Drafts or other air currents affecting

2.

Eliminate source of drafts around heater

pliance off residue before reusing appliance

 

flame pattern

 

 

 

3.

Air holes at burner inlet blocked

3.

Clean out air holes at burner inlet. Peri-

 

 

 

 

odically repeat as needed

 

4.

Burner flame holes blocked

4.

Remove blockage

Manual backgroundFor moreManual backgroundManual backgroundManual backgroundvisit www.Manual backgroundManual backgroundManual background.comManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background

110148-01A

Page 25
Image 25
Desa VYGF33PRB Maintenance, page, ing Gas Connections, page, Troubleshooting, Continued, Observed Problem, Possible Cause