6.Carefully insert fireplace into rough opening.

10

INSTALLATION

Built-In Fireplace Installation

INSTALLATION

Continued

BUILT-IN FIREPLACE INSTALLATION FOR MODELS VYGF33PRB & VYGF33NRB

Built-in installation of this fireplace involves installing fireplace into a framed-in enclosure. This makes the front of fireplace flush with wall. If installing a mantel above the fireplace, you must follow the clearances shown in Figure 20, page 12. Follow the instructions below to install the fireplace in this manner.

 

Actual

 

 

Framing

 

 

 

 

 

Height

32 3/8"

 

 

33"

Front Width

34

5/

16

"

 

35

1/ "

 

 

 

 

 

 

2

Depth

16

11/

16

"

17

3/ "

 

 

 

 

 

 

4

1.Frame in rough opening. Use dimensions shown in Figure 13 for the rough opening.If installing in a corner, use dimensions shown in Figure 14 for the rough opening. The height is 33" which is the same as the wall opening above.

2.If using blower, install and properly ground GA3555, three- prong 120 volt electrical outlet, in fireplace. Follow instruc- tions included in kit (see Accessories, pages 34 and 35).

3.Install gas piping to fireplace location. This installation includes an approved flexible gas line (if allowed by local codes) after the equipment shutoff valve. The flexible gas line must be the last item installed on the gas piping. See Installing Gas Piping to Fireplace Location, pages 12 and 13.

4.Carefully set fireplace in front of rough opening with back of fireplace inside wall opening.

5.Plug electrical cord into electrical outlet installed in step 2.

6.Carefully insert fireplace into rough opening.

7.Attach flexible gas line to gas supply. See Connecting Fire- place to Gas Supply, pages 13 and 14.

8.Attach fireplace to wall studs using nails or wood screws through holes in nailing flange (see Figure 15).

9.Check all gas connections for leaks. See Checking Gas Con- nections, pages 14 and 15.

10.Install brass trim after final finishing and/or painting of wall (see Figure 7, page 8).

39 3/8"

27 7/8"

Manual background 35 1/2" Manual background 55 5/8"

Figure 14 - Rough Opening for Installing in Corner (for Models VYGF33NRB & VYGF33PRB only)

Nails or

Wood

Screws

Nailing Flanges

Figure 15 - Attaching Fireplace to Wall Studs (VYGF33PRB Shown)

BUILT-IN FIREPLACE INSTALLATION FOR MODELS FPVF33PRA & FPVF33NRA

Built-in installation of this fireplace involves installing fireplace into a framed-in enclosure. This makes the front of fireplace flush with wall. If installing a mantel above the fireplace, you must follow the clearances shown in Figure 20, page 12. Follow the instructions below to install the fireplace in this manner.

 

Actual

Framing

 

 

 

Height

32 3/ "

33"

 

8

 

Front Width

34 5/16"

35 1/2"

Depth

16 11/16"

17 3/4"

17 3/4"

33"

Manual backgroundManual background 35 1/2" Manual background

Figure 13 - Rough Opening for Installing in Wall

Manual background WARNING: A qualified electrician must connect electrical wiring to duplex outlet for built-in installa- tion. Follow all local codes.

Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundForManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background.Manual backgroundManual backgroundManual backgroundManual background.comManual backgroundManual backgroundManual backgroundManual backgroundManual background

110148-01A

Page 10
Image 10
Desa VYGF33PRB, VYGF33NRB installation manual Installation, Continued, Carefully insert fireplace into rough opening