OPERATING HEATER

OPERATING HEATER

Thermostatically- Controlled Models

Continued

1.STOP! Read the safety information above.

2.Make sure manual shutoff valve is fully open.

3. Turn control knob clockwise _

to the OFF position.

. g!LniW

ignitor Button.__"

_

_

_COntrOI

KnOb

Figure 23 - Control Knob and Ignitor Button Location

4.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow "B" in the safety information above. If you don't smell gas, go to the next step.

5. Turn control

knob counterclockwise _

to the PILOT position. Press in

control knob

for five (5) seconds (see above).

 

Note: You may be running this heater for the first time after hooking up to gas supply. If so, the control knob may need to be pressed in for 30 seconds or less. This will allow air to bleed from the gas system.

If control knob does not pop out when released, contact a qualified service person or gas supplier for repairs.

6.With control knob pressed in, press and release ignitor button. This will light pilot.

The pilot is attached to the front burner. If needed, keep pressing ignitor button until pilot lights.

Note: If pilot does not stay lit, contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure on page 24.

7.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

Note: If pilot goes out, repeat steps 3 through 7. This heater has a safety inter. lock system. Walt one (1) minute for system to reset before lighting pilot again.

IgnitorElectrode

Thermocouple_

_

mer

_

Figure 24 - Pilot

8.Turn control knob counterclockwise _ burners should light. Set control knob to

to desired heating level. The any heat level between HI and LO.

CAUTION

i

Do not try to adjust heating levels by using the manual shutoff.valve.

Continued I