OPTIONAL POSITIONING
OF
THERMOSTAT SENSING BULB
For Masonry and
Metal Fireplace
Continued
ThermostatL.
Sensing Bulb
i
Mounting Clip
Figure 30 - Locating Thermostat Sensing Bulb on Masonry Fireplace
If you have a
/ kl
Thermostat
Sensing Bulb
Mounting Clip
J
Figure 31 - Locating Thermostat Sensing Bulb on
If your ftreplace has glass doors, position sensing bulb directly behind door gap on right bottom side (see Figure 32).
Thermostat
Sensing Bulb
Mounting Clip
Glass
Doors
Figure 32 - Installing Thermostat Sensing Bulb behind Glass Doors
5.The mounting clip must be a minimum of 3" from bottom of fireplace to prevent crimping of capillary. Once you have decided on a location, clean the area thoroughly. Remove the paper backing from the adhesive on back of mounting clip, Press the clip into the new location so that the thermostat sensing bulb will be positioned vertically with the capillary at the bottom (see Figure 33). Slide the thermostat sensing bulb into the clip.
IMPORTANT: Do not crimp capillary. | Thermostat |
|
|
• | Mounting Clip |
_ | Sensing Bulb |
| Do Not Crimp Capillary |
Figure 33. Positioning the Thermostat Sensing Bulb In the Vertical