UNVENTED PROPANE/LP GAS FIREPLACE
INSTALLATION
Continued
16.Position switch/plate assembly verti- cally over wall openings with decal let- tering upright (see Figure 13).
17.Insert mounting screws, removed in step 2 of Relocating Wall Switch on page 9, through holes in wall plate and into wall anchors.
18.Tighten screws until wall plate is firmly attached to wall. Do not overtighten.
Opening in
Wall or
Mantel Wall
Wall Plate/
Switch
Screws
Figure 13 - Securing Wall Switch
Mounting Wall Switch to Side of Mantel
7.Create three openings in the mantel wall according to Template 2, page 35. This is best done by making a pattern to work with on the mantel. Carefully cut page 35/36 from manual and tape paper tem- plate vertically onto mantel wall at pre- ferred location. Pierce the paper at the centers of the 2 holes with a nail or sharp pencil, leaving a mark on the wall. Do the same at centers of the four circles near the corners of the rectangle.
8.Remove paper template from mantel wall.
9.Drill 1/8" pilot holes at each mark for top and bottom screw holes. Drill 3/8" holes at each mark for centers of four circles near corners of rectangle.
10.Using a straight edge and pencil, con- nect the outer edges of the 4 holes for the rectangle (see Figure 10, page 9). This will give you cutting lines for the rectangle you will cut in the mantel wall.
11.Using a keyhole saw, hack saw blade, drill, file, or other suitable tool, carefully cut out the rectangular opening. Note: The corners of the rectangle may be round. IMPORTANT: Do not exceed the size of the rectangle on template.
12.Carefully pass switch/plate assembly through rectangular opening from in- side mantel (see Figure 13).
13.Position switch/plate assembly vertically over opening with decal lettering upright. Make sure wires freely pass through wall without binding.Align holes in wall plate with 1/8" pilot holes in mantel wall.
14.Drive mounting screws, removed in step 2 of Relocating Wall Switch on page 9, through wall plate holes and into pilot holes in mantel wall.
15.Tighten screws until wall plate is firmly attached to mantel. Do not overtighten.
INSTALLING VARIABLE SPEED BLOWER ACCESSORY
NOTICE:
1.If fireplace screen and floor are still installed, see Removing Fireplace Screen and Floor Assembly, page 8.
2.Attach the power cord to the blower motor by firmly pushing the two female termi- nals at the end of the power cord onto the two spade terminals on the blower motor.
3.Attach green ground wire from power cord to blower housing using screw provided (see Figure 14). Tighten screws securely.
4.Place the blower against lower rear wall of firebox outer wrapper with the ex- haust port directed upward. Align the holes in top mounting tabs of blower with holes in wall of wrapper (see Fig- ure 14). Using 2 screws provided, mount blower and tighten screws securely.
5.Be certain that all wire terminals are securely attached to terminals on blower motor and that the screw retain- ing the green ground wire is tight.
6.Place control knob provided on plastic control shaft of speed control.
7.Mount the speed control on the front leg of the left floor support bracket using 2 screws provided (see Figure 15).
Lower Rear Wall of Firebox
Blower
Screws
Exhaust
Port
Top
Mounting
Tab
Screw
Green Ground Wire
Figure 14 - Mounting Blower to Firebox
Left Floor Support
Bracket
Screws
Speed
Control
Control
Control Shaft
Knob
Figure 15 - Attaching Speed Control to Firebox
For more information, visit www.desatech.com | 10 | 107570 |