Dell E05S001 HyperTransport, Error caused a, For details, Following faulty, DIMMs are, Ignored

Models: E05S E05S001

1 190
Download 190 pages 16.97 Kb
Page 50
Image 50

Message

Causes

Corrective Actions

 

 

 

HyperTransport

A fatal system error occurred

Check the SEL for

error caused a

and caused the system to

information that is logged

system reset!

reboot.

during the error. See the

Please check the

 

applicable troubleshooting

system event log

 

section in "Troubleshooting

for details!

 

Your System" on page 151,

 

 

for any faulty components

 

 

specified in the SEL.

 

 

 

Warning:

Faulty or improperly seated

See "Troubleshooting Your

Following faulty

memory module(s). Check

System" on page 151.

DIMMs are

both DIMMs in the same

 

ignored:

channel for a possible fault.

 

DIMM n1 n2

 

 

Total memory size

 

 

is reduced.

 

 

 

 

 

Warning:

Faulty or improperly seated

See "Troubleshooting Your

Following faulty

memory module(s). Check

System" on page 151.

DIMMs are

both DIMMs in the same

 

disabled:

channel for a possible fault.

 

DIMM n1 n2

 

 

Total memory size

 

 

is reduced.

 

 

 

 

 

Warning: The

Invalid memory

Ensure that the memory

installed memory

configuration. The system

modules are installed in a

configuration is

will run but with reduced

valid configuration. See

not optimal. For

functionality.

"General Memory Module

more information

 

Installation Guidelines" on

on valid memory

 

page 93. If the problem

configurations,

 

persists, see

please see the

 

"Troubleshooting System

system

 

Memory" on page 159.

documentation on

 

 

the technical

 

 

support web site.

 

 

NOTE: For the full name of an abbreviation or acronym used in this table, see the Glossary at support.dell.com/manuals.