Dell E05S001 E1620 Power Supply, # #### W Ac, Power error, Cables, E1624 Lost power, E1629 Power

Models: E05S E05S001

1 190
Download 190 pages 16.97 Kb
Page 28
Image 28

Code

Text

Causes

Corrective Actions

 

 

 

 

E1620

Power Supply

Specified power supply's AC

Check the AC power

 

# (#### W) AC

input is outside the

source for the specified

 

power error.

allowable range.

power supply. If the

 

Check PSU

 

problem persists, see

 

cables.

 

"Troubleshooting Power

 

 

 

Supplies" on page 157.

 

 

 

 

E1624

Lost power

The power supply subsystem

See "Troubleshooting

 

supply

is no longer redundant. If

Power Supplies" on

 

redundancy.

the remaining power supply

page 157.

 

Check PSU

fails, the system will shut

 

 

cables.

down.

 

 

 

 

 

E1629

Power

The system configuration

Turn off power to the

 

required >

requires more power than

system, check if adequate

 

PSU wattage.

the power supplies can

power is supplied to the

 

Check PSU and

provide, even with

system. See the Getting

 

config.

throttling.

Started Guide for

 

 

 

information on the

 

 

 

System power

 

 

 

requirements.

E1631 System power

Processor and memory

draw exceeded

throttling is not sufficient to

threshold.

keep system power

Contact

consumption below the

support.

maximum safe level with

 

the current power supply

 

configuration.

Remove AC power to the system for 10 seconds and restart the system.

If the problem persists, see "Getting Help" on page 185.

E1632 FailSafe

The processors and memory

event.

have been throttled to keep

Contact

system power consumption

support.

below the maximum safe

 

level with current power

 

supply configuration.

Remove AC power to the system for 10 seconds and restart the system.

If the problem persists, see "Getting Help" on page 185.