Dell E05S E2010 Memory not, Inspect, E2011 Memory, Check DIMMs, E2012 Memory, Configured

Models: E05S E05S001

1 190
Download 190 pages 16.97 Kb
Page 33
Image 33

Code

Text

Causes

Corrective Actions

 

 

 

 

E2010

Memory not

No memory detected in the

Install memory or reseat

 

detected.

system.

the memory modules. See

 

Inspect

 

"Installing Memory

 

DIMMs.

 

Modules" on page 97 or

 

 

 

"Troubleshooting System

 

 

 

Memory" on page 159.

 

 

 

 

E2011

Memory

Memory detected, but is not

See "Troubleshooting

 

configuration

configurable. Error detected

System Memory" on

 

failure.

during memory

page 159.

 

Check DIMMs.

configuration.

 

 

 

 

 

E2012

Memory

Memory configured, but is

See "Troubleshooting

 

configured

unusable.

System Memory" on

 

but unusable.

 

page 159.

 

Check DIMMs.

 

 

 

 

 

 

E2013

BIOS unable

The system BIOS failed to

See "Troubleshooting

 

to shadow

copy its flash image into

System Memory" on

 

memory. Check

memory.

page 159.

 

DIMMs.

 

 

 

 

 

 

E2014

CMOS RAM

CMOS failure. CMOS RAM

Remove AC power to the

 

failure.

not functioning properly.

system for 10 seconds and

 

Power cycle

 

restart the system.

 

AC.

 

If the problem persists,

 

 

 

 

 

 

see "Getting Help" on

 

 

 

page 185.

 

 

 

 

E2015

DMA

DMA controller failure.

Remove AC power to the

 

Controller

 

system for 10 seconds and

 

failure.

 

restart the system.

 

Power cycle

 

If the problem persists,

 

AC.

 

 

 

see "Getting Help" on

 

 

 

 

 

 

page 185.

 

 

 

 

E2016

Interrupt

Interrupt controller failure.

Remove AC power to the

 

Controller

 

system for 10 seconds and

 

failure.

 

restart the system.

 

Power cycle

 

If the problem persists,

 

 

 

AC.

see "Getting Help" on

 

 

page 185.

About Your System