Code

Text

Causes

Corrective Actions

 

 

 

 

E1414

CPU # temp

Specified processor is out of

Ensure that the processor

 

exceeding

acceptable temperature

heat sinks are properly

 

range. Check

range.

installed. See

 

CPU heatsink.

 

"Troubleshooting the

 

 

 

Processors" on page 168

 

 

 

and "Troubleshooting

 

 

 

System Cooling

 

 

 

Problems" on page 157.

 

 

 

 

E1418

CPU # not

Specified processor is

Ensure that the specified

 

detected.

missing or bad and the

processor is properly

 

Check CPU is

system is in an unsupported

installed. See

 

seated

configuration.

"Troubleshooting the

 

properly.

 

Processors" on page 168.

 

 

 

E141C Unsupported

Processors are in an

Ensure that your

 

CPU

unsupported configuration.

processors match and

 

configuration

 

conform to the type

 

. Check CPU

 

described in the processor

 

or BIOS

 

technical specifications

 

revision.

 

outlined in your system’s

 

 

 

Getting Started Guide.

E141F CPU #

The system BIOS reported a

protocol

processor protocol error.

error. Power

 

cycle AC.

 

Remove AC power to the system for 10 seconds and restart the system.

If the problem persists, see "Getting Help" on page 185.

E1420 CPU Bus The system BIOS reported a parity error. processor bus parity error. Power cycle

AC.

Remove AC power to the system for 10 seconds and restart the system.

If the problem persists, see "Getting Help" on page 185.

26

About Your System

Page 26
Image 26
Dell E05S001 E1414 CPU # temp, CPU heatsink, E1418 CPU # not, Check CPU is, Seated, Properly, E141C Unsupported, Or Bios