Message

Causes

Corrective Actions

 

 

 

Alert! Node

The memory configuration

Ensure that the memory

Interleaving

has changed (for example, a

modules are installed in a

disabled! Memory

memory module has failed)

configuration that supports

configuration

so that node interleaving

node interleaving. Check

does not support

cannot be supported. The

other system messages for

Node

system will run but without

additional information for

Interleaving.

node interleaving.

possible causes. For memory

 

 

configuration information,

 

 

see "General Memory

 

 

Module Installation

 

 

Guidelines" on page 93. If

 

 

the problem persists, see

 

 

"Troubleshooting System

 

 

Memory" on page 159.

 

 

 

Alert! Power

The system configuration of

If any system components

required exceeds

processor(s), memory

were just upgraded, return

PSU wattage.

modules, and expansion

the system to the previous

Check PSU and

cards may not be supported

configuration. If the system

system

by the power supplies.

boots without this warning,

configuration.

 

then the replaced

Alert!

 

component(s) are not

 

supported with this power

Continuing

 

 

supply. If Energy Smart

system boot

 

 

power supplies are installed,

accepts the risk

 

 

replace them with the High

that system may

 

 

Output power supplies to use

power down

 

 

the components. See "Power

without warning.

 

 

Supplies" on page 85.

 

 

 

 

 

Alert! Redundant

Redundant memory was

Check the memory modules

memory disabled!

enabled in the system setup

for failure. See

Memory

program, but the current

"Troubleshooting System

configuration

configuration does not

Memory" on page 159. Reset

does not support

support redundant memory.

the memory setting, if

redundant

A memory module may be

appropriate. See "Using the

memory.

faulty.

System Setup Program and

 

 

UEFI Boot Manager" on

 

 

page 53.

About Your System

39

Page 39
Image 39
Dell E05S Alert! Node, Interleaving, Disabled! Memory, Does not support, Alert! Power, Required exceeds, Accepts the risk