Dell E05S001 Performance, Degraded. CPU, Memory set to, Frequencies to, Meet PSU wattage

Models: E05S E05S001

1 190
Download 190 pages 16.97 Kb
Page 49
Image 49

Message

Causes

Corrective Actions

 

 

 

Warning! Power

The system configuration of

If any system components

required exceeds

processor(s), memory

were just upgraded, return

PSU wattage.

modules, and expansion

the system to the previous

Check PSU and

cards may not be supported

configuration. If the system

system

by the power supplies.

boots without this warning,

configuration.

 

then the replaced

Warning!

 

component(s) are not

 

supported with this power

Performance

 

 

supply. If Energy Smart

degraded. CPU and

 

 

power supplies are installed,

memory set to

 

 

replace them with High

minimum

 

 

Output power supplies to use

frequencies to

 

 

the components. See "Power

meet PSU wattage.

 

 

Supplies" on page 85.

System will

 

 

 

reboot.

 

 

Write fault

Write fault on selected drive.

Faulty USB device, USB medium, optical drive assembly, hard drive, or hard- drive subsystem.

Replace the USB medium or device. Ensure that the USB, SAS backplane, or SATA cables are properly connected. See "Troubleshooting a USB Device" on page 152, "Troubleshooting an Internal USB Key" on page 161, and "Troubleshooting a Hard Drive" on page 164.

Incorrect memory The DIMM group for CPU n

configuration is incorrectly configured and

CPU n.caused the system to halt.

See "General Memory

Module Installation Guidelines" on page 93, for memory configuration information. If the problem persists, see "Troubleshooting System Memory" on page 159.

About Your System

49

Page 49
Image 49
Dell E05S001 owner manual Performance, Degraded. CPU, Memory set to, Frequencies to, Meet PSU wattage