Dell E05S E171F PCIe fatal, E1810 Hard drive ##, Fault. Review, Clear SEL E1812 Hard drive ##

Models: E05S E05S001

1 190
Download 190 pages 16.97 Kb
Page 31
Image 31

Code Text

Causes

Corrective Actions

 

 

 

E171F PCIe fatal

The system BIOS reported a

Remove and reseat the

error on Bus

PCIe fatal error on a

PCIe expansion cards. If

## Device ##

component that resides in

the problem persists, see

Function ##.

PCI configuration space at

"Troubleshooting

 

bus ##, device ##,

Expansion Cards" on

 

function ##.

page 166.

PCIe fatal The system BIOS reported a error on Slot PCIe fatal error on a

#.Review & component that resides in

clear SEL.

the specified slot.

Remove and reseat the expansion-card riser. See "Expansion Cards and Expansion-Card Risers" on page 107. If the problem persists, the riser card or system board is faulty. See "Getting Help" on page 185.

E1810

Hard drive ##

The specified hard drive

See "Troubleshooting a

 

fault. Review

experienced a fault.

Hard Drive" on page 164.

 

& clear SEL.

 

 

 

 

 

 

E1812

Hard drive ##

The specified hard drive is

Information only.

 

removed.

removed from the system.

 

 

Check drive.

 

 

E1A11 PCI Riser

PCIe risers are not

hardware &

configured correctly. Some

configuration

invalid configurations

mismatch.

prevent the system from

Reconfigure.

powering on.

Reinstall the expansion- card riser. See "Expansion Cards and Expansion- Card Risers" on page 107.

If the problem persists, the riser card or system board is faulty. See "Getting Help" on page 185.

E1A12 PCI Riser not

One or both of the PCIe

detected.

risers are missing. This

Check Riser.

prevents the system from

 

powering on.

Reinstall the missing riser card(s). See "Installing Expansion-Card Riser 1" on page 113 and "Installing Expansion- Card Riser 2" on page 114.

About Your System

31

Page 31
Image 31
Dell E05S E171F PCIe fatal, E1810 Hard drive ##, Fault. Review, Clear SEL E1812 Hard drive ##, Removed, Hardware, Mismatch