Message

Causes

Corrective Actions

 

 

 

No boot sector on

Incorrect configuration

Check the hard-drive

hard drive.

settings in System Setup

configuration settings in the

 

program, or no operating

System Setup program. See

 

system on hard drive.

"Using the System Setup

 

 

Program and UEFI Boot

 

 

Manager" on page 53. If

 

 

necessary, install the

 

 

operating system on your

 

 

hard drive. See your

 

 

operating system

 

 

documentation.

 

 

 

No timer tick

Faulty system board.

See "Getting Help" on

interrupt.

 

page 185.

 

 

 

PCI BIOS failed

PCIe device BIOS (Option

Reseat the expansion card(s).

to install.

ROM) checksum failure

Ensure that all appropriate

 

detected during shadowing.

cables are securely connected

 

Cables to expansion card(s)

to the expansion card(s). If

 

the problem persists, see

 

loose; faulty or improperly

 

"Troubleshooting Expansion

 

installed expansion card(s).

 

Cards" on page 166.

 

 

 

 

 

PCIe Training

Faulty or improperly installed

Reseat the PCIe card in the

Error: Expected

PCIe card in the specified

specified slot number. See

Link Width is x,

slot.

"Troubleshooting Expansion

Actual Link Width

 

Cards" on page 166. If the

is y.

 

problem persists, see

 

 

"Getting Help" on page 185.

 

 

 

Plug & Play

Error encountered in

Install the NVRAM_CLR

Configuration

initializing PCIe device;

jumper in the clear position

Error.

faulty system board.

(pins 1 and 3) and reboot the

 

 

system. See Figure 6-1 for

 

 

jumper location. If the

 

 

problem persists, see

 

 

"Troubleshooting Expansion

 

 

Cards" on page 166.