INSTALLING

INSTALLING

INSTALLATION CLEARANCES

Continued

WARNING ICONG 001 WARNING

Maintain the minimum clearances. If you can, provide greater clearances from floor, ceiling, and adjoining wall.

Carefully follow the instructions below. This will ensure safe installation.

Minimum Wall and Ceiling Clearances (see Figure 7)

A.Clearances from the side of the fireplace opening to any combustible wall should not be less than 16 inches for a cabinet mantel or 12 inches for a corner installation.

B.Clearances from the top of the fireplace opening to the ceiling should not be less than 42 inches.

 

 

MINIMUM CLEARANCE

Note: Clearances

42"

Side Wall - 16 "

are the same if

Ceiling - 42"

 

using optional

 

Floor - 0"

cabinet mantel or

 

 

built-in installation.

 

 

16"

Figure 7 - Minimum Clearance to Wall and Ceiling

CONVENTIONAL FIREPLACE INSTALLATION

Conventional installation of this fireplace involves installing fireplace along with the cabinet mantel and hearth base accessory against a wall in your home. Follow the instructions below to install the fireplace in this manner.

WARNING

WARNING ICON

G 001

For conventional installation, it is recommended you use the cabinet mantel or hearth bases specified in this manual. Surface clearances may not be sufficient with other cabinet mantels and hearth bases. This may create a fire hazard. See Accessories, page 38 for correct mantels and hearth bases.

Note: The instructions below show installation using the GMC11F/GMC12U cabinet mantel and the GC3333F/GC3334U hearth base accessory. The hearth base accessory shown is optional for this installation. You can install fireplace and cabinet mantel directly on the floor.

1.Assemble cabinet mantel and hearth base. Assembly instructions are included with each accessory.