OPERATING FIREPLACE
C-clockwise

OPERATING FIREPLACE

Thermostat- Controlled Model

Continued

22

LIGHTING INSTRUCTIONS

WARNING

WARNING ICON

G 001

You must operate this fireplace with the fireplace screen in place. Make sure fireplace screen is installed before running fireplace.

NOTICE

During initial operation of new fireplace, burning logs will give off a paper-burning smell. Orange flame will also be present. Open window to vent smell. Operate fireplace on HI position to burn off odor. This will only last a few hours.

1.STOP! Read the safety information on page 21.

2.Make sure manual shutoff valve is fully open.

3. Turn control knob clockwise ClockwiseThermostat- Controlled Model to the OFF position.

Control Knob

Ignitor Button

Figure 25 - Control Knob and Ignitor Button Location

4.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information above. If you don’t smell gas, go to the next step.

5. Turn control knob counterclockwise LIGHTING INSTRUCTIONS to the PILOT position. Press in control knob for five (5) seconds (see Figure 25, above).

Note: If running fireplace for first time, there will be air in gas line. You may need to press in control knob for 30 seconds or longer. This will allow air to bleed from the gas system.

6.Continue pressing control knob in. Press and release ignitor button. This will light pilot. The pilot is attached to the front burner. If needed, keep pressing ignitor button until pilot lights.

7.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

If control knob does not pop out when released, contact a qualified service person or gas supplier for repairs.

Note: If pilot goes out, repeat steps 3 through 7. This fireplace has a safety interlock system. Wait one (1) minute for system to reset before lighting pilot again.

Note: If pilot does not stay lit, contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure, page 23.

Thermocouple

Ignitor Electrode

Pilot Burner

Figure 26 - Pilot

102664

Page 22
Image 22
Desa Tech CGF265NVA, CGF280NT Operating Fireplace, Lighting Instructions, Thermostat- Controlled Model, Continued, Pilot