Desa Tech CGF265NVA Manually-ControlledModel, Operating Fireplace, Lighting Instructions, Pilot

Models: CGF265NVA CGF280NT

1 40
Download 40 pages 41.67 Kb
Page 24
Image 24
Manually-Controlled Model
C-clockwise
C-clockwise

OPERATING FIREPLACE

Manually-Controlled Model

Continued

24

LIGHTING INSTRUCTIONS

WARNING

WARNING ICON

G 001

You must operate this fireplace with the fireplace screen in place. Make sure fireplace screen is installed before running fireplace.

NOTICE

During initial operation of new fireplace, burning logs will give off a paper-burning smell. Orange flame will also be present. Open window to vent smell. Operate fireplace on HI position to burn off odor. This will only last a few hours.

1.STOP! Read the safety information on page 23.

2.Make sure manual shutoff valve is fully open.

3. Turn control knob clockwise ClockwiseFigure 28 - Pilot to the OFF position.

Ignitor Button

Control Knob

IGNITOR

Figure 27 - Control Knob and Ignitor Button Location

4.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information above. If you don’t smell gas, go to the next step.

5. Slightly depress and turn control knob counterclockwise Manual background to the PILOT position. Press in control knob for five (5) seconds (see Figure 27, above).

Note: If running fireplace for first time, there will be air in gas line. You may need to press in control knob for 30 seconds or longer. This will allow air to bleed from the gas system.

6.Continue pressing control knob in. Press and release ignitor button. This will light pilot. The pilot is attached to the front burner. If needed, keep pressing ignitor button until pilot lights.

Note: If pilot does not stay lit, contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure, page 25.

7.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

Note: If pilot goes out, repeat steps 3 through 7.

If control knob does not pop out when released, contact a qualified service person or gas supplier for repairs.

Thermocouple

Ignitor Electrode

Pilot Burner

 

Figure 28 - Pilot

8. Slightly depress and turn control knob counterclockwise Manual background to the HIGH position. Both burners should light. Set control knob to either HIGH or LOW.

102664