Desa Tech CGF280NT Cleaning, Maintenance, Trouble, Shooting, can damage ODS/pilot unit, Observed

Models: CGF265NVA CGF280NT

1 40
Download 40 pages 41.67 Kb
Page 27
Image 27
CLEANING

CLEANING

WARNING ICONG 001

 

WARNING

AND

Turn off fireplace and let cool before cleaning.

MAINTENANCE

 

 

 

 

 

 

WARNING ICONG

001

CAUTION

 

You must keep control areas, burners, and circulating air pas- sageways of fireplace clean. Inspect these areas of fireplace before each use. Have fireplace inspected yearly by a qualified service person. Fireplace may need more frequent cleaning due to excessive lint from carpeting, bedding material, etc.

ODS/PILOT AND BURNERS

• Use a vacuum cleaner or small, soft bristled brush to clean.

LOGS

If you remove logs for cleaning, refer to Installing Logs, pages 20 and 21, to properly replace logs.

Replace log(s) if broken or chipped (dime-sized or larger).

TROUBLE-

 

 

WARNING ICONG 001 WARNING

 

 

 

 

SHOOTING

Turn off fireplace and let cool before servicing. Only a qualified

 

 

service person should service and repair fireplace.

 

Note: All troubleshooting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

items are listed in order of

 

 

 

 

 

 

 

 

 

WARNING ICONG 001 CAUTION

 

 

 

 

operation.

 

 

 

 

 

 

 

Never use a wire, needle, or similar object to clean ODS/pilot. This

 

 

can damage ODS/pilot unit.

 

 

 

 

 

 

 

 

 

 

 

 

OBSERVED

POSSIBLE

 

 

 

 

 

PROBLEM

CAUSE

REMEDY

 

 

 

 

 

 

 

 

When ignitor button

1.

Ignitor cable pinched or

1.

Free ignitor cable if

 

is pressed, there is no

 

wet

 

pinched by any metal or

 

spark at ODS/pilot

 

 

 

tubing. Keep ignitor

 

 

 

 

 

cable dry

 

 

2.

Ignitor electrode not con-

2.

Reconnect ignitor cable

 

 

 

nected to ignitor cable

 

 

 

 

 

 

3.

Piezo ignitor nut is loose

3.

Tighten nut holding

 

 

 

 

 

piezo ignitor to base

 

 

 

 

 

panel of log set. Nut is

 

 

 

 

 

located behind base

 

 

 

 

 

panel.

 

 

4.

Broken ignitor cable

4.

Replace ignitor cable

 

 

5.

Ignitor electrode broken

5.

Replace ignitor

 

 

6.

Bad piezo ignitor

6.

Replace piezo ignitor

 

 

7.

Ignitor electrode posi-

7.

Replace ignitor

 

 

 

tioned wrong

 

 

 

 

 

 

 

 

 

Continued

 

 

 

 

 

 

 

 

 

 

 

 

 

 

27

102664

Page 27
Image 27
Desa Tech CGF280NT Cleaning, Maintenance, Trouble, Shooting, can damage ODS/pilot unit, Observed, Possible, Problem, Cause