OWNER’S MANUAL
INSTALLATION
Continued
CONNECTING TO GAS SUPPLY
WARNING: This appliance re- quires a 1/2" NPT (National Pipe Thread) inlet connection to the pressure regulator.
WARNING: A qualified service person must connect heater to gas supply. Follow all local codes.
Installation Items Needed
Before installing heater, make sure you have the items listed below.
•piping (check local codes)
•sealant (resistant to propane/LP gas)
•equipment shutoff valve *
•test gauge connection *
•sediment trap
•tee joint
•pipe wrench
* A CSA |
valve with 1/8" NPT tap is an acceptable |
alternative to test gauge connection. Pur- |
Installation must include a equipment shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from heater (see Figure 18).
IMPORTANT: Install equipment shutoff valve in an accessible location. The equip- ment shutoff valve is for turning on or shutting off the gas to the appliance.
Back Stove |
| |
Panel |
| |
Product | Back View | |
Identification | ||
| ||
Label |
|
Side View | Gas Log | |
Front | Heater | |
| ||
of | Gas Inlet | |
Stove | ||
Connection | ||
Unit | ||
Access | ||
|
Check your building codes for any special requirements for locating equipment shutoff valve to fireplaces.
Apply pipe joint sealant lightly to male NPT threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged heater valves.
WARNING: Use pipe joint seal- ant that is resistant to liquid pe- troleum (LP) gas.
We recommend that you install a sediment trap in supply line as shown in Figure 18. Locate sediment trap where it is within reach for cleaning. Install in piping system between fuel supply and heater. Locate sediment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contami- nants. This keeps them from going into heater controls. If sediment trap is not installed or is installed wrong, heater may not run properly.
CAUTION: Avoid damage to regulator. Hold gas regulator with wrench when connecting it to gas piping and/or fittings.
chase the optional CSA |
equipment shutoff valve from your dealer. |
See Accessories, page 19. |
Figure 17 - Gas Regulator Location and Gas Line Access Into Stove Cabinet
The gas inlet connection for the stove heater is located on the lower
17.Make sure gas log heater is secured to the stove cavity assembly.
WARNING: Never connect heater to private
From Gas Meter (5" W.C.** to 10.5" W.C. Pressure)
Sediment |
| Tee Joint | ||
|
|
| Pipe | |
Trap | ||||
| Nipple | |||
|
|
| ||
|
|
| Cap |
CSA
Equipment Shutoff Valve
With 1/8" NPT Tap*
Approved Flexible Gas Hose (if allowed by local codes)
Gas
Regulator
3" Minimum
CAUTION: Use only new, black iron or steel pipe.
Figure 18 - Gas Connection
*Purchase the optional CSA
**Minimum inlet pressure for purpose of input adjustment.
Continued
104463 | 11 |