CONNECTING TO GAS SUPPLY

OWNER’S MANUAL

INSTALLATION

Continued

CONNECTING TO GAS SUPPLY

Installation Items Needed WARNING: This appliance re- quires a 1/2" NPT (National Pipe Thread) inlet connection to the pressure regulator.

Manual background WARNING: A qualified service person must connect heater to gas supply. Follow all local codes.

Installation Items Needed

Before installing heater, make sure you have the items listed below.

piping (check local codes)

sealant (resistant to propane/LP gas)

equipment shutoff valve *

test gauge connection *

sediment trap

tee joint

pipe wrench

* A CSA design-certified equipment shutoff

valve with 1/8" NPT tap is an acceptable

alternative to test gauge connection. Pur-

Installation must include a equipment shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from heater (see Figure 18).

IMPORTANT: Install equipment shutoff valve in an accessible location. The equip- ment shutoff valve is for turning on or shutting off the gas to the appliance.

Back Stove

 

Panel

 

Product

Back View

Identification

 

Label

 

Side View

Gas Log

Front

Heater

 

of

Gas Inlet

Stove

Connection

Unit

Access

 

Check your building codes for any special requirements for locating equipment shutoff valve to fireplaces.

Apply pipe joint sealant lightly to male NPT threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged heater valves.

Manual backgroundWARNING: Use pipe joint seal- ant that is resistant to liquid pe- troleum (LP) gas.

We recommend that you install a sediment trap in supply line as shown in Figure 18. Locate sediment trap where it is within reach for cleaning. Install in piping system between fuel supply and heater. Locate sediment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contami- nants. This keeps them from going into heater controls. If sediment trap is not installed or is installed wrong, heater may not run properly.

Manual background CAUTION: Avoid damage to regulator. Hold gas regulator with wrench when connecting it to gas piping and/or fittings.

chase the optional CSA design-certified

equipment shutoff valve from your dealer.

See Accessories, page 19.

Figure 17 - Gas Regulator Location and Gas Line Access Into Stove Cabinet

The gas inlet connection for the stove heater is located on the lower right-hand side of the stove when viewed from the front of the unit. The gas connection can be made either through the bottom right side or through the lower back opening as illustrated in Figure

17.Make sure gas log heater is secured to the stove cavity assembly.

Manual background WARNING: Never connect heater to private (non-utility) gas wells. This gas is commonly known as wellhead gas.

From Gas Meter (5" W.C.** to 10.5" W.C. Pressure)

Sediment

 

Tee Joint

 

 

 

Pipe

Trap

 

Nipple

 

 

 

 

 

 

Cap

CSA Design-Certified

Equipment Shutoff Valve

With 1/8" NPT Tap*

Approved Flexible Gas Hose (if allowed by local codes)

Gas

Regulator

Manual backgroundManual backgroundManual background 3" Minimum

Manual backgroundCAUTION: Use only new, black iron or steel pipe. Internally-tinned copper tubing may be used in certain areas. Check your local codes. Use pipe of 1/2" diameter or greater to allow proper gas vol- ume to heater. If pipe is too small, undue loss of volume will occur.

Figure 18 - Gas Connection

*Purchase the optional CSA design-certified equipment shutoff valve from your dealer. See Accessories, page 19.

**Minimum inlet pressure for purpose of input adjustment.

Continued

104463

11

Page 11
Image 11
Desa Tech SL30NT installation manual Continued, Connecting To Gas Supply, Installation Items Needed