OWNER’S MANUAL
INSTALLATION
NOTICE: This heater is intended for use as supplemental heat. Use this heater along with your pri- mary heating system. Do not in- stall this heater as your primary heat source. If you have a central heating system, you may run system’s circulating blower while using heater. This will help circu- late the heat throughout the house. In the event of a power outage, you can use this heater as your primary heat source.
WARNING: A qualified ser- vice person must install heater. Follow all local codes.
NOTICE: State or local codes may only allow operation of this appli-
IMPORTANT:
CHECK GAS TYPE
Use only natural gas. If your gas supply is not natural gas, do not install heater. Call dealer where you bought heater for proper type heater.
CLEARANCES TO
COMBUSTIBLES (Vent-Free Operation Only)
WARNING: Maintain the mini- mum clearances. If you can, pro- vide greater clearances from floor, ceiling, and adjoining side and back walls.
Carefully follow the instructions below. This stove is a freestanding unit designed to set directly on the floor. IMPORTANT: You must maintain minimum wall and ceiling clearances during installation. The mini- mum clearances are shown in Figure 4. Measure from outermost point of stove top.
Minimum Wall and Ceiling Clearances (see Figure 4)
A.Clearances from outermost point of stove top to any combustible side wall should not be less than 12 inches.
B.Clearances from outermost point of stove top to any combustible back wall should not be less than 6 inches (In- cludes Corner Installations).
C.Clearances from the stove top to the ceiling should not be less than 48 inches.
ance in a vented configuration. Check your state or local codes.
WARNING: Never install the heater
• in a bedroom or bathroom |
• in a recreational vehicle |
• where curtains, furniture, |
clothing, or other flammable |
objects are less than 42 inches |
from the front, top, or sides of |
Ceiling
Front View
48"
Minimum
Side Wall | 12" |
|
|
|
|
|
|
| 12" | Side Wall | |||||||
Minimum |
|
|
|
|
|
|
| Minimum | |||||||||
|
|
|
|
|
|
|
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| the heater |
• | in high traffic areas |
• | in windy or drafty areas |
CAUTION: This heater cre- ates warm air currents. These currents move heat to wall sur- faces next to heater. Installing heater next to vinyl or cloth wall coverings or operating heater where impurities (such as, but not limited to, tobacco smoke, aromatic candles, cleaning flu- ids, oil or kerosene lamps, etc.) in the air exist, may discolor walls or cause odors.
Top View
Back Wall
|
| 6 " |
|
| Minimum |
| 12 " | 12 " |
| Minimum | Minimum |
Side Wall |
|
|
Corner | Wall |
|
| 6 " | Front of |
| Minimum | |
|
| Stove Unit |
Wall | 6 " |
| Minimum |
|
|
Side View
Ceiling
Side Wall
48"
Minimum
Back Wall
6"
Minimum
Floor
Figure 4 - Minimum Clearance to Walls and Ceiling (Stove May Vary Depending on
Model) | Continued |
|
104463 | 7 |