MAINTENANCE

WHEN DOING MAINTENANCE, YOU MAY BE EXPOSED TO HOT SURFACES, WATER PRESSURE, MOVING PARTS, OR FIRE RESULTING IN DEATH. BEFORE PERFORMING ANY MAINTENANCE OR REPAIR, DISCONNECT SPARK PLUG WIRE, LET ENGINE COOL AND RELEASE ALL WATER PRESSURE. THE ENGINE CONTAINS FLAMMABLE FUEL. DO NOT SMOKE OR WORK NEAR OPEN FLAMES WHILE PERFORMING MAINTENANCE.

To ensure efficient operation and longer life of your pressure washer, a routine maintenance schedule should be prepared and followed. The following routine maintenance schedule is geared to an unit in a normal working environment. If necessary, the schedule should be modified to suit the conditions under which your pressure washer is used. The modifications will depend upon the hours of operation and the working environment. If the pressure washer is in an extremely dirty and/or hostile environment it will require a greater frequency of all maintenance checks.

1.Consult the Engine Owners Manual for the manufacturer's recommendations for any and all maintenance.

2.Pump oil (checking and changing). Refer to the following illustrations to identify which pump is on your pressure washer. Refer to the chart for oil type, oil capacity, and maintenance schedule (if applicable).

 

 

 

Pump

 

 

 

Oil Type

Oil Capacity

 

Change Oil

 

 

 

 

 

 

 

 

 

 

 

First 10

after

 

 

 

 

 

 

 

 

 

 

 

every 50

* never

 

 

 

 

 

 

 

 

 

 

 

hours

 

 

 

 

 

 

 

 

 

 

hours

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Annovi Reverberi (XJV)

 

 

10W30 synthetic

5.25 oz

 

 

x

 

 

 

 

 

Annovi Reverberi (XJW)

 

 

10W30 synthetic

5.25 oz

 

 

x

 

 

 

 

 

Annovi Reverberi (XMV)

 

 

30W non detergent

13.5 oz

x

x

 

 

 

 

 

 

Annovi Reverberi (XRV)

 

 

30W non detergent

18.54 oz

x

x

 

 

 

 

 

 

Annovi Reverberi (XTV)

 

 

30W non detergent

9.92 oz

x

x

 

 

 

 

 

 

Cat

 

 

30W non detergent

bottom of sight glass

x

x

 

 

 

 

 

 

DeVilbiss (horizontal)

 

 

 

** R&0 150

8 oz

x

x

 

 

 

 

 

 

DeVilbiss (vertical)

 

 

 

** R&0 150

10 oz

x

x

 

 

 

 

 

 

Faip

 

 

15W-50 synthetic

4 oz

 

 

x

 

 

 

 

 

Giant (HR series)

 

 

***20W50 synthetic

4.5 oz

 

 

x

 

 

 

 

 

Giant (model P316)

 

 

***20W50 synthetic

17 oz

x

x

 

 

 

 

 

 

Giant (model P303)

 

 

***20W50 synthetic

14 oz

x

x

 

 

 

 

 

 

General

 

 

30W non detergent

4 oz

x

x

 

 

 

 

 

 

Karcher

 

**15W40 non detergent

4 oz

 

 

x

 

 

 

 

* These pumps do not require the oil to be changed, the oil will last the lifetime of the pump. In the unlikely

 

 

 

 

event of an oil leak, remove all oil and add the correct amount.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

** If unable to find use 30W non detergent

 

 

 

 

 

 

 

 

 

*** If unable to find use 15W50 synthetic

 

 

 

 

 

 

The following pump (1500-2200

The following pumps (1500-2200 psi) are shipped from the

psi) is shipped from the factory

 

factory with 15W-50 synthetic oil:

with 15W40 non detergent oil:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Karcher

Faip (Horizontal)

Faip (Vertical)

16 — ENG