DeVillbiss Air Power Company D26968 warranty Grounding the Generator, Extension Cords

Models: D26968

1 72
Download 72 pages 53.44 Kb
Page 12
Image 12

GROUNDING THE GENERATOR

A grounding lug is supplied with the generator for use when required by local electrical ordinances. Refer to article 250 of the National Electrical Code to clarify any needed grounding information. Your local electric company or a certified electrician should be able to help you with this information.

Grounding Lug

OBTAINING ELECTRICITY FROM THE GENERATOR

There are basically 2 ways to obtain electricity from a generator:

1.Use of extension cords directly from the generator to the appliance, lights, tools, etc.

2.Use of a double-throw transfer switch installed directly to the main electrical supply outside of house.

EXTENSION CORDS

When using an appliance or tool at a considerable distance from the generator, a 3-wire extension cord that has a 3- blade grounding plug and a 3-slot recep- tacle that accepts the tool's plug MUST be used in order to reduce the risk of electrical shock. A cord of adequate size must be used. Using the following chart to determine the minimum wire size re- quired.

An extension cord that is hot to the touch is

overloaded. Repair or replace damaged extension cords immediately.

Extension Cord Wire Gauge Chart

Cord

Wire

 

Amperage

Length

Gauge

 

 

 

 

Size

 

 

0 to 100 ft.

12 ga.

1

Up to 20 amp draw

 

 

 

 

0 to 100 ft.

10 ga.

2

Up to 30 amp draw

 

 

 

 

0 to 100 ft.

8 ga.

 

Up to 40 amp draw

 

 

 

 

1.When amperage exceeds 20 amp; a 12 gauge extension cord should not be used for long distances.

2.When amperage exceeds 30 amp; a 10 gauge extension cord should not be used for long distances.

DOUBLE THROW TRANSFER SWITCH

Potential hazards exist when a portable electric generator is connected to the main electrical supply coming into the house.

It is at that point that the electrical generator could feed back into the utility company's system causing possible electrocution of workers who are repairing the electrical lines.

To avoid back feeding of electricity into utility systems, a double-throw transfer switch must be installed between the generator and utility power. The Double- Throw Transfer Switch should be installed by a licensed electrician and in com- pliance with all state and local electrical codes. (When installing a Double-

Throw Transfer Switch, a minimum of 10 gauge wiring must be used.)

The electrician should also install a sub-panel to isolate the circuits you would want to use during an emergency or electrical power outage. Your generator will not be large enough to handle the load of all the lights, appliances, TV, etc. at one time. To select which items to run during the electrical power outage, see Wattage Calculation section in this manual.

D26968

12- ENG

Page 12
Image 12
DeVillbiss Air Power Company D26968 Grounding the Generator, Obtaining Electricity from the Generator, Extension Cords

D26968 specifications

The DeVillbiss Air Power Company D26968 is a remarkable pneumatic tool that has gained recognition for its performance and versatility in various applications. With a focus on delivering efficient and reliable air-powered solutions, the D26968 is designed for both professional and enthusiast users looking to tackle a wide range of tasks, including painting, sanding, and surface preparation.

One of the most notable features of the D26968 is its robust construction. Built with high-quality materials, it is engineered to withstand the rigors of demanding work environments, ensuring longevity and durability. This heavy-duty design not only contributes to the tool's lifespan but also enhances its overall performance, making it a reliable choice for users.

The D26968 is equipped with advanced technologies that set it apart from its competitors. Its precision-engineered features provide optimal airflow and pressure control, allowing users to achieve consistent results across various applications. The adjustable pressure regulator is a standout component, enabling operators to fine-tune the airflow to suit specific tasks, which enhances both efficiency and finish quality.

Another significant characteristic of the D26968 is its ergonomics. Designed with user comfort in mind, this tool features a lightweight body and an easy-to-grip handle, reducing fatigue during extended periods of use. The balanced weight distribution minimizes strain, allowing users to work efficiently without compromising on comfort.

Additionally, the D26968 incorporates a quick-connect coupling system that streamlines setup and teardown processes. This feature not only saves time but also ensures that the tool is compatible with a wide range of air hoses, providing users with added flexibility.

Safety is also a priority with the D26968. The integrated safety mechanisms protect against accidental discharges and over-pressurization, ensuring the user's peace of mind while working. Furthermore, regular maintenance is made simple with easily accessible components, allowing for effortless upkeep and prolonged tool life.

In summary, the DeVillbiss Air Power Company D26968 stands out as a high-performance pneumatic tool that embodies durability, precision, and comfort. Its combination of innovative technologies and practical features makes it an excellent choice for both novice and experienced users, effectively addressing the demands of various air-powered tasks and enhancing overall productivity in any workshop setting.