RISK OF ELECTROCUTION AND FIRE (Continued)

HAZARD

 

 

WHAT CAN HAPPEN

HOW TO PREVENT IT

 

 

 

 

 

 

Operation of

 

Water is an excellent conductor

Operate generator in a clean, dry,

generator in rain,

 

of electricity! Water which comes

well ventilated area. Make sure

wet, icy, or

 

in contact with electrically

hands are dry before touching

flooded

 

charged components can

unit.

conditions.

 

transmit electricity to the frame

 

 

 

 

 

and other surfaces, resulting in

 

 

 

 

 

electrical shock to anyone con-

 

 

 

 

 

tacting them.

 

 

 

 

 

 

 

 

 

Use of worn,

 

Contact with worn or damaged

Inspect extension cords before

damaged, under-

 

extension cords could result in

use and replace with new cord if

sized or un-

 

electrocution.

required.

grounded exten-

 

 

 

 

 

 

 

 

Use of undersize extension

Use proper size (wire gauge)

sion cords.

 

 

 

cords could result in overheating

cordset for application see chart

 

 

of the wires or attached items,

in the Assembly section of this

 

 

resulting in fire.

manual.

 

 

 

 

 

 

 

Use of ungrounded cordsets

Always use a cordset having a

 

 

could prevent operation of

grounding wire with an

 

 

circuit breakers and result in

appropriate grounding plug. DO

 

 

electrical shock.

NOT use an ungrounded plug.

 

 

 

 

 

 

 

Placing generator

 

 

Accidental leakage of electrical

Place generator on low conduc-

on or against

 

 

current could charge conductive

tivity surface such as a concrete

highly conductive

 

 

surfaces in contact with the

slab.

surface, such as a

 

 

generator.

 

 

 

steel walkway or

 

 

 

 

ALWAYS operate generator a

metal roof.

 

 

 

 

minimum of six feet from any

 

 

 

 

 

conductive surface.

Improper

 

Exceeding the load capacity of

Read the load rating chart and

connection of

 

the generator by attaching too

instructions in the Wattage Cal-

items to

 

many items, or items with very

culation section. Make sure that

generator.

 

high load ratings to it could

the summation of electrical

 

 

result in overheating of some

loads for all attachments does

 

 

items or their attachment wiring

not exceed the load rating of the

 

 

resulting in fire or electrical

generator.

 

 

shock.

 

 

 

 

 

 

 

 

 

 

 

Operation of unit

 

 

 

 

Do not operate generator with

 

 

Attempting to use the unit

when damaged,

 

 

when it has been damaged, or

 

mechanical or electrical

or with guards or

 

 

when it is not functioning

 

problem. Have unit repaired by

panels removed.

 

 

normally could result in fire or

 

an Authorized Service Center.

 

 

 

electrocution.

 

 

 

 

 

 

 

Removal of guarding could

Do not operate generator with

 

 

 

expose electrically charged

protective guarding removed.

 

 

 

components and result in

 

 

 

 

 

 

electrocution.

 

 

 

D26968

4- ENG

Page 4
Image 4
DeVillbiss Air Power Company D26968 Risk of Electrocution and Fire, Operation, Generator in rain, Wet, icy, or, Flooded

D26968 specifications

The DeVillbiss Air Power Company D26968 is a remarkable pneumatic tool that has gained recognition for its performance and versatility in various applications. With a focus on delivering efficient and reliable air-powered solutions, the D26968 is designed for both professional and enthusiast users looking to tackle a wide range of tasks, including painting, sanding, and surface preparation.

One of the most notable features of the D26968 is its robust construction. Built with high-quality materials, it is engineered to withstand the rigors of demanding work environments, ensuring longevity and durability. This heavy-duty design not only contributes to the tool's lifespan but also enhances its overall performance, making it a reliable choice for users.

The D26968 is equipped with advanced technologies that set it apart from its competitors. Its precision-engineered features provide optimal airflow and pressure control, allowing users to achieve consistent results across various applications. The adjustable pressure regulator is a standout component, enabling operators to fine-tune the airflow to suit specific tasks, which enhances both efficiency and finish quality.

Another significant characteristic of the D26968 is its ergonomics. Designed with user comfort in mind, this tool features a lightweight body and an easy-to-grip handle, reducing fatigue during extended periods of use. The balanced weight distribution minimizes strain, allowing users to work efficiently without compromising on comfort.

Additionally, the D26968 incorporates a quick-connect coupling system that streamlines setup and teardown processes. This feature not only saves time but also ensures that the tool is compatible with a wide range of air hoses, providing users with added flexibility.

Safety is also a priority with the D26968. The integrated safety mechanisms protect against accidental discharges and over-pressurization, ensuring the user's peace of mind while working. Furthermore, regular maintenance is made simple with easily accessible components, allowing for effortless upkeep and prolonged tool life.

In summary, the DeVillbiss Air Power Company D26968 stands out as a high-performance pneumatic tool that embodies durability, precision, and comfort. Its combination of innovative technologies and practical features makes it an excellent choice for both novice and experienced users, effectively addressing the demands of various air-powered tasks and enhancing overall productivity in any workshop setting.