GENERATOR MAINTENANCE

Your generator should be kept clean and dry at all times. The generator should not be stored or operated in environments that includes excessive moisture, dust or any corrosive vapors. If these substances are on the generator, clean with a cloth or soft bristle brush. Do not use a garden hose or anything with water pressure to clean the generator. Water may enter the cooling air slots and could possibly damage the rotor, stator and the internal windings of the gen head.

GROUND FAULT CIRCUIT INTERRUPTER GFCI RECEPTACLE

MONTHLY: For maximum protection against electrical shock the GFCI should be tested monthly.

To test:

1.Depress the TEST button. The RESET button should extend. If the RESET button does not extend, notify a DeVilbiss Air Power Company Authorized Warranty Service Center.

2.To restore power, depress the RESET button firmly into the GFCI unit until an audible click is heard. If reset properly, the RESET button is flush with the surface of the test button. When the button stays in, the power is ON.

STORAGE

If you are going to store your generator for more than 30 days, use the following information as a guide to prepare the generator for storage.

Never store generator with fuel in the tank indoors or in enclosed, poorly ventilated areas, where fumes can reach

an open flame, spark or pilot light as on a furnace, water heater, clothes dryer or other gas appliances.

ENGINE PREPARATION

1.Add fuel stabilizer to fuel tank to minimize the formation of fuel gum deposits during storage.

2.Run engine at least 10 minutes after adding stabilizer to allow it to enter the fuel system.

3.Next shut off engine.

4.Disconnect the spark plug wire and remove the spark plug.

5.Add one teaspoon of oil through the spark plug hole.

6.Place rag over spark plug hole and pull the recoil a few times to lubricate the combustion chamber.

7.Replace the spark plug, but do not connect the spark plug wire.

NOTE: If a fuel stabilizer is not used, all gasoline must be drained from the tank and carburetor to prevent gum deposits from forming on these parts and causing possible malfunction of the engine.

GENERATOR

Clean the generator as outlined in the Maintenance Section on this manual.

Check that cooling air slots and openings on generator are open and unobstructed.

17- ENG

D26968

Page 17
Image 17
DeVillbiss Air Power Company D26968 Storage, Generator Maintenance, Ground Fault Circuit Interrupter Gfci Receptacle

D26968 specifications

The DeVillbiss Air Power Company D26968 is a remarkable pneumatic tool that has gained recognition for its performance and versatility in various applications. With a focus on delivering efficient and reliable air-powered solutions, the D26968 is designed for both professional and enthusiast users looking to tackle a wide range of tasks, including painting, sanding, and surface preparation.

One of the most notable features of the D26968 is its robust construction. Built with high-quality materials, it is engineered to withstand the rigors of demanding work environments, ensuring longevity and durability. This heavy-duty design not only contributes to the tool's lifespan but also enhances its overall performance, making it a reliable choice for users.

The D26968 is equipped with advanced technologies that set it apart from its competitors. Its precision-engineered features provide optimal airflow and pressure control, allowing users to achieve consistent results across various applications. The adjustable pressure regulator is a standout component, enabling operators to fine-tune the airflow to suit specific tasks, which enhances both efficiency and finish quality.

Another significant characteristic of the D26968 is its ergonomics. Designed with user comfort in mind, this tool features a lightweight body and an easy-to-grip handle, reducing fatigue during extended periods of use. The balanced weight distribution minimizes strain, allowing users to work efficiently without compromising on comfort.

Additionally, the D26968 incorporates a quick-connect coupling system that streamlines setup and teardown processes. This feature not only saves time but also ensures that the tool is compatible with a wide range of air hoses, providing users with added flexibility.

Safety is also a priority with the D26968. The integrated safety mechanisms protect against accidental discharges and over-pressurization, ensuring the user's peace of mind while working. Furthermore, regular maintenance is made simple with easily accessible components, allowing for effortless upkeep and prolonged tool life.

In summary, the DeVillbiss Air Power Company D26968 stands out as a high-performance pneumatic tool that embodies durability, precision, and comfort. Its combination of innovative technologies and practical features makes it an excellent choice for both novice and experienced users, effectively addressing the demands of various air-powered tasks and enhancing overall productivity in any workshop setting.