Westward Operating Instructions and Parts Manual

Model 3JR70A

 

 

Portable Air Compressor

Symptom (s)

Motor will not run.

Possible Causes (s)

1.Fuse blown, circuit breaker tripped.

2.Extension cord is wrong length or gauge.

3.Loose electrical connections.

4.Faulty motor.

Corrective Actions (s)

1a. Check fuse box for blown fuse and replace as necessary.

Reset circuit breaker. Do not use a fuse or circuit breaker with higher rating than that specified for your particular branch circuit.

b.Check for proper fuse. You should use a time delay fuse.

c.Check for low voltage problem.

d.Check the extension cord.

e.Disconnect the other electrical appliances from circuit or operate the compressor on its own branch circuit.

2.Check the extension cord.

3.Check wiring connection inside terminal box.

4.Have checked by a trained service technician.

18- ENG

Page 18