DeWalt 3JR70A HOW to Stop, Before First START-UP, Before Each START-UP, HOW to Start

Models: 3JR70A

1 72
Download 72 pages 21.12 Kb
Page 12
Image 12

Westward Operating Instructions and Parts Manual

Model 3JR70A

 

 

Portable Air Compressor

HOW TO STOP

1.Set the On/Auto/Off lever to "OFF".

BEFORE FIRST START-UP

Serious damage may result if the

following break-in instructions are not closely followed.

This procedure is required before the air compressor is put into service and when the check valve or a complete compressor pump has been replaced.

1.Make sure the On/Auto/Off lever is in the "OFF" position.

NOTE: Pull coupler back until it clicks to prevent air from escaping through the quick connect.

2.Plug the power cord into the correct branch circuit receptacle. (Refer to Voltage and Circuit Protection paragraph in the Installation section of this manual.)

3.Open the drain valve fully (counter-clockwise) to permit air to escape and prevent air pressure build up in the air tank during the break-in period.

NOTE: Always drain tank on a washable surface or in a suitable container to prevent damaging or staining surfaces.

4.Move the On/Auto/Off lever to "ON/AUTO" position. The compressor will start.

5.Run the compressor for 15 minutes. Make sure the drain valve is open and there is minimal air pressure build-up in tank.

6.After 15 minutes, close the drain valve (clockwise). The air receiver will fill to "cut-out" pressure and the motor will stop. will stop.

The compressor is now ready for use.

BEFORE EACH START-UP

1.Place On/Auto/Off lever to "OFF".

2.Turn the regulator knob counterclockwise to set the outlet pressure to zero.

3.Attach hose and accessories. NOTE: The hose or accessory will require a quick connect plug if the air outlet is equipped with a quick connect socket.

Too much air pressure causes a

hazardous risk of bursting. Check the manufacturer’s maximum pressure rating for air tools and accessories. The regulator outlet pressure must never exceed the maximum pressure rating.

HOW TO START

1.Turn the On/Auto/Off lever to "AUTO" and allow tank pressure to build. Motor will stop when tank pressure reaches "cut-out" pressure.

2.Turn regulator knob clockwise to increase pressure and stop when desired pressure is reached.

NOTE: Always operate the air compressor in well-ventilated areas free of gasoline or other combustible vapors. If the compressor is being used to operate a sprayer DO NOT place near the spray area.