DeWalt 3JR70A specifications Storage, Regulator Arrow

Models: 3JR70A

1 72
Download 72 pages 21.12 Kb
Page 15
Image 15

Westward Operating Instructions and Parts Manual

Model 3JR70A

 

 

Portable Air Compressor

To Replace Regulator (continued)

NOTE: Arrow indicates flow of air. Make sure it is pointing in the direction of air flow.

Regulator

Arrow

7.Reapply pipe sealant to gauges and quick connect.

8.Reassemble gauges and quick connect. Orient gauges to read correctly. Tighten quick connect with wrench.

Storage

Water will condense in the

air tank. If not drained, water will corrode and weaken the air tank causing a risk of air tank rupture.

Before you store the air compressor, make sure you do the following:

1. Review the "Maintenance" section on the preceding pages and perform scheduled maintenance as necessary.

2.Set the On/Auto/Off lever to "OFF".

3.Turn the regulator counterclockwise and set the outlet pressure to zero.

4.Remove the air tool or accessory.

5.Pull ring on safety valve allowing air to bleed from the tank until tank pressure is approximately 20 psi. Release safety valve ring.

6.Drain water from air tank by opening drain valve on bottom of tank.

7.After the water has been drained, close the drain or drain valve.

NOTE: If drain valve is plugged, release all air pressure. The valve can then be removed, cleaned, and reinstalled.

8.Protect the electrical cord and air hose from damage (such as being stepped on or run over). Wind them loosely around the compressor handle. (If so equipped)

Store the air compressor in a clean and dry location.

15- ENG

Page 15
Image 15
DeWalt 3JR70A specifications Storage, Regulator Arrow