Westward Operating Instructions and Parts ManualModel 3JR70A
Portable Air Compressor
Symptom (s) | Possible Causes (s) | Corrective Actions (s) | ||
Pressure reading | 1. | It is normal for "some" | 1. | If there is an excessive |
on the regulated |
| pressure drop to occur. |
| amount of pressure drop |
pressure gauge |
|
|
| when the accessory is |
drops when an |
|
|
| used, adjust the regulator |
accessory is |
|
|
| following the instructions |
used. |
|
|
| in the "Description of |
|
|
|
| Operation" paragraph in |
|
|
|
| the "Operation Section. |
|
|
| NOTE: Adjust the regulated | |
|
|
| pressure under flow | |
|
|
| conditions (while accessory is | |
|
|
| being used). | |
|
|
| ||
Compressor is not 1. Prolonged excessive use | 1. | Decrease amount of air | ||
supplying enough |
| of air. |
| usage. |
air to operate |
|
| 2. | Check the accessory |
accessories. | 2. | Compressor is not | ||
|
| large enough for air |
| air requirement. If it is |
|
| requirement. |
| higher than the SCFM |
|
|
|
| or pressure supplied |
|
|
|
| by your air compressor, |
|
|
|
| you need a larger |
|
|
|
| compressor. |
| 3. | Hole in hose. | 3. | Check and replace if |
|
|
|
| required. |
| 4. | Check valve restricted. | 4. | Remove and clean, or |
|
|
|
| replace. |
| 5. | Air leaks. | 5. | Tighten fittings. |
|
|
|
|
|
Regulator knob | 1. | Damaged regulator | 1. | Replace |
has continuous |
|
|
|
|
air leak. |
|
|
|
|
|
|
|
|
|
Regulator will | 1. | Damaged regulator | 1. | Replace |
not shut off air |
|
|
|
|
outlet. |
|
|
|
|
17- ENG