5.Run the compressor for 15 minutes.

6.After 15 minutes, close the drain valve by turning clockwise. The tank will fill to cut-outpressure and the motor will stop.

7.Compressed air will be available until it is used or bled off.

OPERATING PROCEDURES

Start-up (Fig. 1)

1.Follow Pre-Start Checklist under Preparation for Use.

CAUTION: Risk of unsafe operation. Do not operate in upright position. Upright position is for storage only.

2.Move the On/Off switch to the ON position and allow tank pres- sure to build. Motor will stop when tank pressure reaches cut-outpressure.

CAUTION: Risk of unsafe operation. Compressed air from the unit may contain water condensation and oil mist. Do not spray unfil- tered air at an item that could be damaged by moisture. Some air operated tools or devices may require filtered air. Read the instruc- tions for the air tool or device.

3.Adjust regulator (F) to desired setting. See Regulator under Features.

Shut-down (Fig. 1)

1.Move On/Off switch (L) to the OFF position. NOTE: If finished using compressor, follow Steps 2 – 6.

2.Turn regulator knob (F) counterclockwise until fully closed. Ensure regulated pressure gauge reads 0 PSI (0 kPa).

3.Remove hose and accessory.

4.Drain the air tank, see Draining Air Tank under Maintenance. Ensure air tank pressure gauge reads 0 PSI (0 kPa).

WARNING: Risk of bursting. Drain air tank daily. Water will con- dense in air tank. If not drained, water will corrode and weaken the air tank causing a risk of air tank rupture.

5.Allow the compressor to cool down.

6.Wipe air compressor clean and store in a safe, non-freezing area.

CAUTION: Risk of unsafe operation. Do not operate in upright position. Upright position is for storage only.

MAINTENANCE

The following procedures must be followed when maintenance or service is performed on the air compressor.

1.Ensure On/Off switch is in the OFF position.

2.Remove air compressor plug from outlet.

3.Drain air tank.

4.Allow air compressor to cool down before starting service. NOTE: All compressed air systems contain maintenance parts (e.g., oil, filters, separators) that are periodically replaced. These used parts may contain substances that are regulated and must be disposed of in accordance with local, state, and federal laws and regulations. NOTE: Take note of the positions and locations of parts during disassembly to make reassembly easier.

NOTE: Any service operations not included in this section should be performed by a DEWALT factory service center or a DEWALT authorized service center.

English

13

Page 13
Image 13
DeWalt D55146R instruction manual Operating Procedures, Start-up Fig, Shut-down Fig, Maintenance