DeWalt D55146R instruction manual Troubleshooting Guide, Troubleshooting Codes, Problem Code

Models: D55146R

1 64
Download 64 pages 46.32 Kb
Page 17
Image 17

Troubleshooting Guide

This section provides a list of the more frequently encountered malfunctions, their causes and corrective actions.The operator or maintenance personnel can perform some corrective actions, and others may require the assistance of a qualified DEWALT technician or your dealer.

Problem

 

 

Code

Excessive air tank pressure-safety valve pops off

1,2

Air leaks

....................................................................................................................................

3

Air leaks in air tank or at air tank welds

4

Air leaks between head and valve plate

5

Air leaks from safety valve

6

Knocking Noise

6,16,17

Pressure reading on the regulated pressure gauge drops when an accessory is used

7

Compressor is not supplying enough air to operate accessories

8,9,10,11,12,15

Regulator knob has continuous air leak

13

Regulator will not shut off air outlet

13

Moisture in pump crankcase

14,18

Motor will not run

11,19,20,21,22,23,24

 

Troubleshooting Codes

 

CODE

POSSIBLE CAUSE

POSSIBLE SOLUTION

1

Pressure switch does not shut off motor when compressor

Set the On/Off switch to OFF, if the unit does not shut

 

reaches cut-out pressure

off contact a DEWALT factory service center or a DEWALT

 

 

authorized service center.

2

Pressure switch cut-outtoo high

Contact a DEWALT factory service center or a DEWALT

 

 

authorized service center.

3

Tube fittings are not tight enough

Tighten fittings where air can be heard escaping. Check

 

 

fittings with soapy water solution. Do Not Overtighten.

English

17

Page 17
Image 17
DeWalt D55146R Troubleshooting Guide, Troubleshooting Codes, Problem Code, Code Possible Cause Possible Solution