DeWalt D55146R instruction manual Preparation for USE, Pre-Start Checklist Fig, Initial Set-up Fig

Models: D55146R

1 64
Download 64 pages 46.32 Kb
Page 12
Image 12

B

English

A

B

A

 

B

 

 

2. Pull handle (A) until fully extended (lock position).

WARNING: Risk of unsafe operation. Ensure proper footing and use caution when rolling compressor so that unit does not tip or cause loss of balance.

3.To move, roll compressor on tires using handle (A) as shown above.

Store compressor in a vertical or horzitional position.

PREPARATION FOR USE

Pre-Start Checklist (Fig. 1)

1.Ensure the On/Off switch (L) is in the OFF position.

2.Plug the power cord into the correct branch circuit receptacle. See Voltage and Circuit Protection under Installation.

3.Ensure air tank is drained, see Draining Air Tank under Maintenance.

4.Ensure the drain valve is closed.

5.Ensure safety valve (G) is functioning properly, see Checking Safety Valve under Maintenance.

6.Turn regulator knob (F) counterclockwise until fully closed. Ensure regulated pressure gauge reads 0 PSI (0 kPa).

7.Attach hose and accessories. NOTE: Always use a minimum 3/8" or greater air hose rated at 300 PSI.

WARNING: Risk of unsafe operation. Firmly grasp hose in hand when installing or disconnecting to prevent hose whip.

8.Ensure all covers and labels are in place, legible (for labels) and securely mounted. Do not use compressor until all items have been verified.

WARNING: Risk of bursting. Too much air pressure causes a hazardous risk of bursting. Check the manufacturer’s maximum pressure rating for air tools and accessories. The regulator outlet pressure must never exceed the maximum pressure rating.

Initial Set-up (Fig. 1)

WARNING: Do not operate this unit until you read and understand this instruction manual for safety, operation and maintenance instructions.

BREAK-IN PROCEDURE

CAUTION: Risk of unsafe operation. Be sure compressor is in horizontal position before operating.

CAUTION: Risk of property damage. Serious damage may result if the following break-in instructions are not closely followed.

This procedure is required before the air compressor is put into service for the first time and when the compressor pump/motor has been replaced.

1.Ensure the On/Off switch (L) is in the OFF position.

NOTE: If hose is not connected to Quick Connect body, pull coupler back until it clicks to prevent air from escaping through the quick connect.

2.Plug the power cord into the correct branch circuit receptacle. See Voltage and Circuit Protection under Installation.

3.Open the drain valve (counterclockwise) fully to permit air to escape and prevent air pressure build up in the air tank during the break-in period.

4.Move the On/Off switch to the ON position. The compressor will start.

12

Page 12
Image 12
DeWalt D55146R instruction manual Preparation for USE, Pre-Start Checklist Fig, Initial Set-up Fig, BREAK-IN Procedure