English
Troubleshooting Guide
This section provides a list of the more frequently encountered malfunctions, their causes and corrective actions.The operator or maintenance personnel can perform some corrective actions, and others may require the assistance of a qualified DeWalt technician or your dealer.
Problem |
|
| Code |
Excessive air tank | 1, 2 | ||
Air leaks | ..................................................................................................................................... | 3 | |
Air leaks in air tank or at air tank welds | 4 | ||
Air leaks between head and valve plate | 5 | ||
Air leaks from safety valve | 6 | ||
Knocking Noise | 6 | ||
Pressure reading on the regulated pressure gauge drops when an accessory is used | 7 | ||
Compressor is not supplying enough air to operate accessories | 8, 9, 10, 11, 12, 22 | ||
Regulator knob has continuous air leak | 13 | ||
Regulator will not shut off air outlet | 13 | ||
Motor will not run | 6, 14, 15, 16, 17, 18, 19, 20 | ||
Squealing Sound | 21 | ||
| Troubleshooting Codes |
| |
Code | possible cause | POSSIBLE SOLUTION |
|
1 | Pressure switch does not shut off motor when | Set the Auto/Off switch to OFF, if the unit does not shut off contact | |
| compressor reaches | a DeWALT factory service center or a DeWALT authorized service | |
|
| center. |
|
2 | Pressure switch | Contact a DeWALT factory service center or a DeWALT authorized | |
|
| service center. |
|
3 | Tube fittings are not tight enough | Tighten fittings where air can be heard escaping. Check fittings | |
|
| with soapy water solution. Do Not Overtighten. |
16