Chapter 2

 

 

 

 

Table 2-1:Operating Mode

 

 

 

 

 

 

 

 

 

 

 

 

D3

D4

Mode

Description

 

 

 

 

Up

Up

Normal

Does not allow a Telnet session. Users can print to the

 

 

 

 

 

unit. The SYS (system) LED and NET (network) LED blink.

 

 

 

 

Down

Up

Telnet Diagnostic

Allows a Telnet session to monitor FastPort or change its

 

 

 

 

Monitor

parameters. Users can print to the unit. The SYS LED and

 

 

 

 

 

NET LED blink.

 

 

 

 

Down

Down

Serial Diagnostic

A terminal can be attached to serial port 2 to run a serial

 

 

 

 

Monitor

monitor. Print jobs are not accepted. The NET LED blink.

 

 

 

 

Up

Down

Test Page

A test page prints on a power cycle. No print jobs are

 

 

 

 

 

accepted.

 

 

 

 

 

 

I

N S T A L L

1SERIALPARALLEL

FASTPORT TM

4 PORT NETWORK PRINT SERVER

MODEL MIL•3200X

S1S2

1

2

3

4

P2

 

 

P1

PARALLELSERIAL 2

A

T

I

O N

Figure 2-1. MIL-3200X Front Panel

Table 2-2: Flash and Test Page Select

Switch

Position

Mode

Description

 

 

 

 

D1

Up

Flash

Selects bank 0 (upper) to run the 4 Mb Flash EPROMs for

 

 

Bank

uploading the new firmware image.

 

 

 

 

 

Down

 

Selects bank 1 (lower) to run the 4 Mb Flash EPROMs for

 

 

 

uploading. If the upgrade process fails, use this setting and

 

 

 

power cycle the unit to return FastPort to its default settings.

 

 

 

 

D2

Up

Test Page

MIL-3200X selects parallel port 2 and serial port 2 for test page

 

 

 

printing.

 

 

 

 

 

Down

 

MIL-3200X selects parallel port 1 and serial port 1 for test page

 

 

 

printing.

 

 

 

 

Table 2-3: Default Settings

D1

D2

D3

D4

 

 

 

 

 

 

 

 

Up

Down

Down

Up

MIL-3200X Series of FastPort Print Servers