7.Remove the two shipping bolts located on the front of the pump mount (circled in illustration).
8.If the spa has a bleeder valve in the skimmer area (see picture at right) remove it to allow air to escape from the pump(s) while filling the spa. To remove the bleeder, unscrew it until it comes all the way out of the spa wall.
Note: Don’t forget to replace the bleeder valve later after the pumps are operational.
9.Remove the skimmer canister lid and then remove the foam blocks securing the filter (see photo at right). Remove the filter and fill the spa with a hose placed in the empty filter canister. (For a detailed description of opening the skimmer canister and removing the filter, see the Filter Cleaning section in the Routine Equipment Maintenance section of this manual).
10.Fill the spa until the water level is about 6 inches (15 cm) below the top of the spa.
11.Once the spa is filled, replace the filters and turn on the power at the GFCI circuit breaker. Push the JETS Button twice (use the JETS 1 Button on
If the jets do not start, there is air trapped in the plumbing lines. To eliminate the trapped air, turn the pumps on and off several times to force the trapped air through the pumps. If the jets still do not start, and the bleeder valves have been open for some time, turn off the pumps and loosen the top pump unions (see illustration in step 6) slightly to let any trapped air escape.