10 www.dimplex.com
Fireplace Installation
Option #2: A new outlet can be
installed inside the framing
construction.
Plug the unit into a 15 Amp, 120
Volt outlet. If the cord does not
reach, you may use an extension
cord rated for a minimum of
1875 Watts.
Existing Fireplace
Seal all drafts and vents 1.
with a non-brous insulation
material to prevent any
chimney debris from falling
onto the replace. Do
not install into an existing
replace that is prone to
dampness.
Cap the top of the chimney 2.
ue to prevent rain from
entering.
Plan your electric power 3.
supply.
The power cord can run along 4.
the front of the hearth to an
outlet near the replace.
CAUTION: Clearance for
air circulation beneath the
replace insert is provided
by two (2) spacers. Do not
install the replace insert
directly on carpet or similar
surfaces which may restrict
air circulation. If installing
the replace in a carpeted
area, place a one-piece, solid,
at surface under the replace
insert. Ensure that all feet rest
securely on this surface.
For Bathroom Use
If this unit is installed in a bath-
room it must be protected by
a GFI receptacle or circuit. If
receptacle is used it must be
readily accessible. To prevent
electrical shock this unit is an
electrical appliance that is not
watertight and must be installed
as to prevent water from entering
unit. This must be installed away
from showers, tubs, etc. never
locate replace where it may fall
into a bathtub or other water con-
tainer. High temperatures may be
generated under certain abnormal
conditions. Do not partially or fully
cover or obstruct the front of this
heater.