9
26 ¾”
(679 mm)
23 ⅛”
(587 mm)
9”
(229 mm)
Figure 4
Dimensions without trim are 26
¼ inch (663 mm) wide x 22 ⅞
inch (580 mm) high x 8 ¾ inch
(222 mm) deep. The replace
does not require any additional
venting (Figure 3).
Fireplace Insert Installation
Install the replace assembly
into the mantel (refer to mantel
assembly instructions).
! NOTE 1: A 15 Amp, 120
Volt circuit is required. A
dedicated circuit is preferred
but not essential in all cases.
A dedicated circuit will be
required if after installation the
circuit breaker trips or fuse
blows on a regular basis when
the heater is operating.
Additional appliances
on the same circuit may
exceed the current rating of
the circuit breaker.
! IMPORTANT: If not using
a Dimplex mantel, the
replace must be installed
in an enclosure with
the following MINIMUM
dimensions (Figure 4).
New Wall Construction
select a suitable location that 1.
is not susceptible to moisture
and is away from drapes,
furniture and high trafc.
Place the replace in the 2.
desired location to see how it
will look in the room.
mark the desired location on 3.
the oor.
Use studs to frame an 4.
opening of 26 ¾ inch (679
mm) wide x 23 ⅛ inch (587
mm) high x 9 inch (229 mm)
deep.
Option #1: The power cord can
be run from behind the Trim
and along the wall to an outlet
near the replace.
Fireplace Installation