Dimplex DFG3033 owner manual Glass Cleaning, Maintenance, Upper Light Bulb Requirements

Models: DFG3033

1 22
Download 22 pages 24.91 Kb
Page 17
Image 17
Upper Light Bulb

Do not exceed 15 Watts per bulb. Maintenance

Figure 10

Exploded view to show detail

Flicker Rod

Flicker

Bulbs (3)

Motor

7.Insert new bulb(s).

8.Push flicker rod back onto motor shaft and replace opposite end of flicker rod back into support bracket.

9.Replace media tray back into firebox.

10.Gently pour and evenly spread the glass media.

11.Replace glass assembly.

Upper Light Bulb

Requirements

Quantity of two (2) clear chandelier or candelabra bulbs with an E-12 (small) socket base, 15 Watt rating.

Do not exceed 15 Watts per bulb.

To access the upper light bulb area:

1.Carefully remove the front glass assembly. Be aware

that some of the glass media may fall out of the tray (Figure 9).

2.Upper bulbs are located in the upper left and upper right corners of fireplace (Figure

9).

3.Remove the upper light cover for each bulb (two (2) Philips screws each).

4.Unscrew bulb(s) counter clockwise.

5.Insert new bulb(s).

6.Re-install upper light bracket.

7.Replace glass assembly.

Glass Cleaning

The glass is cleaned in the factory during the assembly operation. During shipment, installation, handling, etc., the glass may collect dust particles; these can be removed by dusting lightly with a clean dry cloth.

To remove fingerprints or other marks, the glass can be cleaned with a damp cloth. To prevent scratching, do not use abrasive cleaners or spray liquids on the glass surface.