Dimplex DFG3033 owner manual Fireplace Installation, Option #3 - Hardwire

Models: DFG3033

1 22
Download 22 pages 24.91 Kb
Page 9
Image 9
Option #3 - Hardwire

Manual background Fireplace Installation

3.Mark the desired location on the floor and store the fireplace in a safe, dry and dust free location.

4.Use studs to frame an opening of 31 ¾ inches (807

mm)wide x 22 ¾ inches (578

mm)high x 9 ½ inches (241

mm)deep.

Option #1 - The power cord can be lead from behind the trim and along the wall to an outlet near the fireplace.

Option #2 - A new outlet can be installed inside the new frame construction. Plug the unit into a 15 Amp, 120 Volt outlet. If the cord does not reach, you may use an extension cord rated for a minimum of 1875 Watts.

Option #3 - Hardwire

1.Wire a dedicated, properly fused circuit with 120 Volt, 15 Amp rating. Allow up to eight

(8) feet (2.4 m) of service cable for connecting power supply to junction box on fireplace when installing after finishing wall.

Manual background CAUTION: Use two conductor, non-metallic sheath cable with ground wire (three

(3) wires total) for the incoming

Figure 2

power supply on fireplace inserts. Use appropriate wire to meet local and national electrical codes for rated power consumption.

2.Remove the outer jacket and strip the individual conductor from the end.

3.Loosen the screw securing the junction box cover and remove the cover.

Figure 3

9

Page 9
Image 9
Dimplex DFG3033 owner manual Fireplace Installation, Option #3 - Hardwire