Dixi manual Parameter Map, Range, dIXEL, Operating Instructions XWA11V, 1598003200

Models: XWA11V

1 8
Download 8 pages 2.89 Kb
Page 7
Image 7
13. PARAMETER MAP

dIXEL

Operating Instructions XWA11V

1598003200

 

 

 

13. PARAMETER MAP

 

 

COOLER

 

**

 

 

 

 

 

 

VALUES

 

FREEZER

 

 

RANGE

 

LABEL

DESCRIPTION

DEFAULT

 

VALUES

LEVEL

 

 

 

 

 

 

 

 

 

[-12,0°C <> 12,0°C] [-

 

ot

Thermostat probe calibration

0

0

Pr2

 

21°F <> 21°F]

CF

Temp measurement unit

F

 

F

Pr2

 

°C - °F

rES

Resolution (only °C)

in

 

in

Pr2

 

dE - in

UT

Display update

60

60

Pr2

 

0 <> 255 (sec)

OnF

Off function enabling

Y

 

Y

Pr2

 

N - Y

 

 

 

 

 

 

 

°C[ ALL <> 150,0°]

ALU

High Temp alarm setting **

50

30

Pr1

 

°F[ ALL <> 302°]

 

 

 

 

 

 

 

°C[ -50.0° <> ALU]

ALL

Low Temp alarm setting **

25

-20

Pr1

 

°F[-58 <> ALU]

 

 

 

 

 

 

 

[0,1°C <>25,5°C]

AFH

Temp alarm differential

2

2

Pr2

 

[1°F <> 45°F]

ALd

Temp alarm delay

30

30

Pr1

 

0 <> 255 (min.)

dAo

Delay of Temp alarm at start-up

1.5

1.5

Pr2

 

0 <> 24.0 (Hrs / 10 min.)

EdA

Alarm delay at the end of defrost

30

30

Pr2

 

0 <> 255 (min.)

 

Delay of Temp alarm after closing

 

 

 

 

 

 

 

dot

the door

15

15

Pr2

 

0 <> 255 (min.)

LHt

Light timer

15

15

Pr1

 

0 <> 255 (min.)

doA

Open door alarm delay

15

15

Pr1

 

0 <> 255 (min.)

OA1

First relay configuration

Alr

 

ALr

Pr2

 

ALr - LHt - OnF

oA2

Second relay configuration

LHt

 

LHt

Pr2

 

ALr - LHt - OnF

AOP

Alarm relay polarity

CL

 

CL

Pr2

 

OP - CL

i1P

Digital input 1 polarity

op

 

oP

Pr2

 

OP - CL

i1L

Door switch to turn light ON

y

 

y

Pr2

 

n - Y

i1F

Digital input 1 operating mode

dor

 

dor

Pr2

 

EAL - dor- dFr - LHt

i2P

Digital input 2 polarity

CL

 

cL

Pr2

 

OP - CL

i2F

Digital input 2 operating mode

Pan

 

PAn

Pr2

 

EAL - Pan - dFr - LHt

 

Time interval/delay for digital

 

 

 

 

 

 

 

did

input alarm

0

0

Pr2

 

0 <> 255 (min.)

tbA

Alarm relay disabling

n

 

n

Pr2

 

n - Y

PbC

Kind of probe

ntc

 

ntc

Pr2

 

PtC - ntC

dP1

Real T° Probe 1

 

 

 

Pr2

 

(probe value)

rEL

FW release

 

 

 

Pr2

 

read only

Ptb

Parameter map

 

 

 

Pr2

 

read only

Weiss Instruments, Inc. 905 Waverly Ave. Holtsville, NY 11742 631-207-1200 www.weissinstruments.com