Dixi XWA11V manual Parameter List, Eal

Models: XWA11V

1 8
Download 8 pages 2.89 Kb
Page 8
Image 8

dIXEL

Operating Instructions XWA11V

1598003200

 

 

 

 

 

 

 

 

 

 

 

 

 

14.

PARAMETER LIST

 

 

 

Ot

Thermostat probe calibration: (-12.012.0°C/ -2121°F) allows to adjust possible offset of the

 

 

 

thermostat probe.

 

 

 

CF

T measurement unit: °C = Celsius; °F = Fahrenheit. When the measurement unit is changed the Set

 

 

 

Point and the values of some parameters have to be modified.

 

 

rES

Resolution (for °C): (in = 1°C; dE = 0.1 °C) allows decimal point display.

 

 

Ut

Display update: The time delay of the T readout (0÷255s)

 

 

onF

Off function enabling: n = off function disabled; y = off function enabled;

 

 

ALU

High T° alarm setting: (ALL 150°C or 302°F);

 

 

 

 

when this T° is reached and after the ALd delay time the HA alarm is enabled.

 

 

ALL

Low T° alarm setting: (- 50°C or -58°F ALU)

 

 

 

 

when this T° is reached and after the ALd delay time, the LA alarm is enabled,.

 

 

AFH

T° alarm differential: (0,1÷25,5°C; 1÷45°F) differential for T° alarm Set Point and fan regulation Set

 

 

 

Point, always a positive value

 

 

ALd

T° alarm delay: (0÷255 min) time interval between the detection of an alarm condition and the

 

 

 

corresponding alarm signaling.

 

 

dAO

Delay of T° alarm at start-up: (0min÷23h 50min) time interval between the detection of the T° alarm

 

 

 

condition after the instrument power on and the alarm signaling.

 

 

EdA

Alarm delay at the end of defrost: (0255 min) Time interval between the detection of the T° alarm

 

 

 

condition at the end of defrost and the alarm signaling.

 

 

dot

Delay of T° alarm after closing the door: (0255 min) Time delay to signal the T° alarm

condition

 

 

 

after closing the door.

 

 

 

LHt

Light timer: (0-255 min) The time the light will stay on after pressing the light switch on the keyboard.

 

doA

Open door alarm delay:(0÷255 min) delay between the detection of the open door condition and its

 

 

 

alarm signaling: the flashing message “dA” is displayed.

 

 

oA1

First relay configuration:

(14-15): ALr = alarm; LHt = light; onF = on/off relay

 

 

oA2

Second relay configuration: (14-16): ALr = alarm; LHt = light; onF = on/off relay

 

 

AOP

Alarm relay polarity: cL = closing contacts; oP = opening contacts.

 

 

i1P

Digital input 1 polarity (1-2): CL : the digital input is activated by closing the contact;

 

 

OP

the digital input is activated by opening the contact

 

 

i1L

Door switch to turn light ON(1-2):(y / no) To turn the light ON automatically when the door is open.

 

 

 

The light will turn off based on LHt . Keyboard switch must be turned ON first.

 

 

i1F

Digital input 1 operating mode(1-2): EAL = external alarm; dor = door switch; dFr = A defrost is

 

 

 

running; LHt = keep light ON (signal from occupancy sensor) override LHt.;

 

 

i2P

Digital input 2 polarity (1-3): CL : the digital input is activated by closing the contact;

 

 

OP

the digital input is activated by opening the contact

 

 

i2F

Digital input 2 operating mode: configure the digital input function:

 

 

EAL

= External alarm;

 

 

 

PAn

=Panic alarm;

 

 

 

dFr = A defrost is running;

 

 

 

LHt = Keep light ON (signal from occupancy sensor) override LHt.

 

 

did

Time interval/delay for digital input alarm:(0255 min.) If I2F=EAL or PAn (external alarms), “did”

 

 

 

parameter defines the time delay between the detection and the successive signaling of the alarm.

 

tbA

Alarm relay & Buzzer disabling: (y ; no)

 

 

Pbc

Type of probe (PTC, NTC)

 

 

 

dP1

Probe 1 T

 

 

 

rEL

Software release for internal use.

 

 

Ptb

Parameter table code: read only.

 

 