CARE AND MAINTENANCE
HYDROSTATIC PUMPS:
Before each use, check to be sure that the cooling fins of the hydrostatic pumps are clean. Excessive accu- mulation of oil, dirt, or trash may cause the pumps to overheat. NEVER WASH ACROSS TOP OF RESER- VOIR WITH WATER OR STEAM. Fill reservoir as required per the maintenance schedule listed in this book.
HYDROSTAT DRIVE BELT REPLACEMENT PROCEDURE:
To remove hydrostat pump drive belt:
(The hydrostat pump drive is equipped with a spring loaded belt
1.Raise seat.
2.Remove hold down bolts from belt cover. Remove belt cover.
3.Rotate the spring loaded
4.Remove belt.
To install hydrostat pump drive belt:
1.Rotate the spring loaded
2.Install belt per diagram.
3.
4.Return the seat to the operating position.