operation

Weak Battery

WARNING!

Lead-acid batteries generate explosive gases. Keep sparks, flame and smoking materials away from batteries. Always wear eye protection when around batteries.

IMPORTANT INFORMATION

Your mower is equipped with a 12-volt negative grounded system. The other vehicle must also be a 12-volt negative grounded system. Do not use your mower to start other vehicles.

If your battery is too weak to start the engine, it should be recharged. (See Battery in the Maintenance section.)

If jumper cables are used for emergency starting, follow this procedure:

Jumper cables

1.

Connect each end of the RED cable to the

 

 

 

 

 

 

 

 

 

 

 

POSITIVE (+) terminal on each battery, taking

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

care not to short against chassis.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2.

Connect one end of the BLACK cable to the

 

 

 

 

 

 

 

 

 

 

 

NEGATIVE (-) terminal of the fully charged battery.

 

 

 

 

 

 

 

 

 

 

3.

Connect the other end of the BLACK cable to a

 

 

 

 

 

 

 

 

 

 

 

good CHASSIS GROUND on the mower with the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

discharged battery, away from the fuel tank and

 

 

 

 

 

 

 

 

 

 

 

battery.

 

 

 

 

 

 

 

 

 

 

 

8011-642

 

 

To remove cables, reverse order

Jumper cable connection

1.Remove BLACK cable first from chassis and then from the fully charged battery.

2.Remove RED cable last from both batteries.