2.2.5 Number of Rings to Ring Residence
Default setting is 05 (5 Rings).
When the CALL button on the 1812 is pushed, this programming sequence sets the number of
unanswered rings to the house before the 1812 hangs up.
1. Press * 6 4 and then enter the MASTER CODE. [ * 6 4 _ _ _ _ (beep)]
2. Enter the number of rings before 1812 hangs up (01-99) then press *. [ _ _ * (beep)]
3. Press 0# TOGETHER to end. [0# (beeeeeep)]
2.2.6 Talk Time
Default setting is 060 (60 Seconds).
This programming sequence sets the maximum time allowed for conversation when the 1812 places
a call to the resident’s house, or if call forwarding is active, or if any of the dial out numbers are used.
Talk time can be set from 10 seconds up to 255 seconds (4 minutes, 15 seconds) and is entered as a
three-digit number. For example, to set a talk time of 30 seconds, enter 030 in step 2.
1. Press * 0 8 and enter the MASTER CODE. [ * 0 8 _ _ _ _ (beep)]
2. Enter the talk time code (010-255) then press *. [ _ _ _ * (beep)]
3. Press 0# TOGETHER to end. [0# (beeeeeep)]
2.2.7 Relay Strike Time
Default setting for Both Relays is 01 (1 Second).
These steps will program Relay 1 and Relay 2 strike times. Strike times can be programmed from 1/4
second (enter 00 in step 3) up to 99 seconds.
1. Press * 0 3 and enter the MASTER CODE. [ * 0 3 _ _ _ _ (beep)]
2. Press 1 * to set relay 1, OR 2 * to set relay 2 strike time. [ _ * (beep)]
3. Enter the two-digit strike time (00-99) then press *. [ _ _ * (beep)]
4. Repeat steps 2 and 3 to set other relay strike time.
5. Press 0# TOGETHER to end. [0# (beeeeeep)]
1812-161-E-1-10 Page 25