2.4.4 Delete All Access Codes 2.4.5 Temporary Access Code Programming 2.4.6 Delete Temporary Access Codes 2.4.7 Delete All Temporary Access Codes
This programming sequence deletes all access codes.
WARNING: Once started, all access codes will be erased.
1. Press * 7 2 and enter the MASTER CODE. [ * 7 2 _ _ _ _ (beep)]
2. Press 2 *. [ 2 * (beep)]
3. Press 9 9 9 9 then press *. [ 9 9 9 9 * (beep)]
4. The programming sequence will end itself automatically. [beeeeeep]
This programming sequence programs up to 10 temporary access codes, with a beginning and
ending date and any time zone restrictions that may need to be applied.
1. Press * 7 3 and enter the MASTER CODE. [ * 7 3 _ _ _ _ (beep)]
2. Press 2 *. [ 2 * (beep)]
3. Enter a five-digit access code then press *. [ _ _ _ _ _ * (beep)]
4. Enter the beginning month (01-12) and day (01-31) then press *. [ _ _ _ _ * (beep)]
5. Enter the ending month (01-12) and day (01-31) then press *. [ _ _ _ _ * (beep)]
6. Enter a minimum of 1, and a maximum 4 time zones (valid time zones are 0 through 6)
that you want to apply to this access code, then press *. [ _ _ _ _ * (beep)]
Time zone 0 is always deny access, time zone 1 allows 24/7 access for relay 1 only; time
zone 2 allows 24/7 access for relay 2 only. Time zones 3, 4, 5 and 6 are time zones that
have been programmed in 2.5.6.
7. Press 0 * for momentary relay activation OR press 1 * to hold (latch) the relay.
[ _ * (beep)]
8. Repeat steps 2 through 7 to program additional temporary access codes.
9. Press 0# TOGETHER to end. [0# (beeeeeep)]
This programming sequence deletes temporary access codes that have been programmed into the
system.
1. Press * 7 4 and enter the MASTER CODE. [ * 7 4 _ _ _ _ (beep)]
2. Press 2 *. [ 2 * (beep)]
3. Enter a five-digit access code then press *. [ _ _ _ _ _ * (beep)]
4. Repeat steps 2 and 3 to delete additional access code numbers.
5. Press 0# TOGETHER to end. [0# (beeeeeep)]
This programming sequence deletes all (10) temporary access codes that have been programmed
into the system.
WARNING: Once started, all temporary access codes will be erased.
1. Press * 7 5 and enter the MASTER CODE. [ * 7 5 _ _ _ _ (beep)]
2. Press 9 9 9 9 then press *. [ 9 9 9 9 * (beep)]
3. The programming sequence will end itself automatically. [beeeeeep]
1812-161-E-1-10 Page 31