2.2.8 Tone Open Numbers
Default setting for Relay 1 is 9876. Default setting for Relay 2 is 5432.
These steps will program the tone open number(s) for both relay 1 and relay 2 (each relay is
programmed independently). You will need to enter a four-digit number (see chart below) to set each
relay. If a function is not desired, enter # in place of a number. For example, if you want the relay to
have a momentary activation function only, and you want the relay to activate when the number 9 is
pressed, enter 9 # # # in step 3.
Note: Hold and Hold 1 hour will not function when a call is made via dialing a directory
number.
1. Press * 0 5 and enter the MASTER CODE. [ * 0 5 _ _ _ _ (beep)]
2. Press 1 * to set relay 1, OR press 2 * to set relay 2. [ _ * (beep)]
3. Enter the four-digit tone open number code then press *. [ _ _ _ _ * (beep)]
4. Repeat steps 2 and 3 to set the other relay tone open number(s).
5. Press 0# TOGETHER to end. [0# (beeeeeep)]
4 Digit Tone
Open
Number
Code
Function
1st Digit Momentary activation. The relay will activate for its programmed strike time.
2nd Digit Hold open. The relay will activate and remain activated until commanded to deactivate.
3rd Digit Deactivate relay.
4th Digit Hold open 1 hour. The relay will activate for 1 hour and then deactivate itself.
2.2.9 Answer Incoming Call on X Rings
Default setting is 06 (6 Rings).
This programming section sets the number of rings that the 1812 will allow to pass through the
system before it picks up the call. The number of rings to answer can be set from 1 to 99 rings and
must be entered as a two-digit number. For example, if you want the 1812 to answer the call after the
sixth ring, enter 0 6 in step 2. If you program 00 in step 2, this will prevent (disable) the 1812 from
answering incoming calls to it.
Important! If more than one 1812 is connected in the system (2.2.2 set for multiple systems), the
1812 that is connected directly to the house phones must have the “Answer Incoming Call” set for
one less ring than the other 1812 units connected in the system.
1. Press * 1 8 and enter the MASTER CODE. [ * 1 8 _ _ _ _ (beep)]
2. Enter the number of rings (01 – 99) then press *. [ _ _ * (beep)]
(enter 00 in this step to disable this feature)
3. Press 0# TOGETHER to end. [0# (beeeeeep)]
1812 # 1
5 Rings 1812 # 2
6 Rings 1812 # 3
6 Rings 1812 # 4
6 Rings
Answer
Machine
4 Rings
Page 26 1812-161-E-1-10