SECTION 1 - INSTALLATION
Prior to beginning the installation of the slide gate operator, we suggest that you become familiar with
the instructions, illustrations, and wiring guide-lines in this manual. This will help insure that your
installation is performed in an efficient and professional manner. The proper installation of the
vehicular slide gate operator is an extremely important and integral part of the overall access control
system. Check all local building ordinances and building codes prior to installing this operator. Be
sure your installation is in compliance with local codes.

1.1 Specifications

Class of Operation: Class III, IV
Type of Gate: Vehicular Slide Gates Only
Horsepower: 9210/9220: 1 HP; 9230: 3 HP
Voltage / Phase: 9210/9220: 115, 208, 230 VAC 1Ø / 208, 230 VAC 3Ø
9230: 208, 230 VAC 3Ø
Current: 9210/9220: 1Ø: 15 A @ 115V, 7.5 A @ 208V, 7.4 A @ 230V
9210/9220: 3Ø: 3.4 A @ 208V, 3.3 A @ 230V
9230 3Ø: 12.4 A @ 208/230V
Max Gate Wt.1 9210: 3000 Lbs; 9220: 2000 Lbs; 9230: 5000 Lbs.
Max Gate Length: 100 Feet
Cycles / Hr: 60/Hr
Speed: 9210: Approx 1 Ft./Sec.
9220/9230: Adjustable ½ - 2 Ft./Sec.
Entrapment Protection: Primary – Inherent (Type A)
Secondary – Provision for connection of a non-contact
sensor (Type B1) and/or a contact sensor (Type B2).
Secondary entrapment protection devices are not supplied
with the operator and must be ordered separately.
Note 1: Assumes gate is in good working condition installed on a
level surface.
35.25
16
2
16
9210-065-H-8-08 Page 15